Laserfiche WebLink
April 27, 1994 <br /> <br />APPLICA/~T~ <br />SITE NUMBER: <br /> <br />STANDARD SYSTEM CONSTRUCTION DETAIL SHEET <br /> <br />LARRY FJ~UDELL <br />94-1575, PARTITION, 3 OF 6 ACRES. NORTH PO T/L 200 <br /> <br /> Your site has been found suitable for a STANDARD ON-SITE SEWAGE DISPOSAL <br />SYSTEM. The following construction specifications shall apply to the installa- <br />tion of your septic system. <br /> <br /> 1. The septic tank shall have a minimum liquid capacity of 1000 <br /> gallons. <br /> <br /> 2. The projected daily sewage flow for this project is calculated at <br /> 450 gallons per day. Based on soil conditions observed on this <br /> site, the disposal field will be si~ed at 15O l%neal feet Der 150 <br /> qallons of projected daily sewage flow. A minimum of 450 lineal <br /> feet of disposal field will be required for your proposed develop- <br /> ment. The disposal trenches are constructed two (2) feet wide and <br /> on minimum ten (10) foot centers and with no line exceeding 125 <br /> feet in length. The trenches and perforated pipe are installed <br /> level (±1") and contoured to follow the natural ground surface. <br /> <br /> 3. The disposal field shall be constructed with serial distrib~tiqq <br /> with a minimum trench depth of 24 inches and a maximum trench <br /> depth of 24 inches. There must be at least 12 inches of backfill <br /> over the top of the gravel, measured from the natural ground <br /> <br /> A groundwater interceptor is required as part of this system. This <br />interceptor trench must be constructed a minimum twelve (12) inches wide by 42 <br />inches deep with 36 inches of clean gravel placed over a four (4) inch smooth <br />wall perforated pipe. The interceptor must be located at least ten (10) feet <br />upslope from the disposal field and must discharge through a watertight, non- <br />perforated pipe beside or below the disposal field. A separation of 25 feet is <br />required from the septic tank if the tank is located upslope of the groundwa- <br />ter interceptor. <br /> <br /> An effluent lift pump may be necessary to construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> This approval is site Specific to the area tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS: <br /> Construct the drainfields within the immediate area of the test pits and <br /> no farther downslope. Avoid the concave landform. A pre-permit field <br /> stakeout will be necessary to establish the location and elevations of <br /> the individual drainfield lines for both system. Refer to the stakeout <br /> procedure and the setback list for details to complete the stakeout. <br /> Note, especially the separation distance between the septic tank and <br /> curtain drain depending upon whether the tank is above or below the <br /> curtain drain. Siting wells should be deferred pending the stakeout <br /> review. Soil conditions are marginal for standard system construction so <br /> use care not alter the natural topsoil prior to drainfield installation. <br /> <br />THIS IS NOT A PEEMIT TO INSTALL THE S~PTIC SYSTEM. DO NOT INSTALL THE SYSTEM <br />UNTIL A VALID PERMIT HAS B~N ISSUED BY THIS OFFICE. <br /> <br /> <br />