06/16/94 14;32 ~5036900744 )~ILBOXE$ 1261 ~002,'003 <br /> <br />12993 Ehlen Rd. NE. Aurora <br />June 13, 1994 <br />~age 2 <br /> <br />hangers are installed on one o~ beth sides of :his multiple me~ber beam. <br />A, How ars the loads o£ the floor joi~ts ~ransferred through all three <br />2x12's when the teco nails used in hangers are 1 1/2" long and will only <br />lead one 2x12 not all three? submit design calculationm for the d~sign <br />of the multiple 2x12 beam or submit a detail of how %he loads are <br /> <br />E. One of the multiple 2xl2's proposed are undersized for the loads. <br />submit a revised beam size. <br /> <br /> How i$ the required separa~ion between workshop/~aragm and habitable <br />space of the dwelling provided at the sBairway to the foyer and to ~he <br />£-.~2~ vaulted storage area above especially in light of the two open areas in <br /> ~th~ vaulted ~toraqe area to the workshop/garage ~elow which are not <br /> permitted. Revis~ the plans and submit revisions for review. <br /> <br /> How is a ~eparation provided between the in~ulated/hea~ed a~a9 o~ the <br /> dwelling and the Uninsulated/unheated/unfinished areas Of the dwelling <br /> provided. Provide revised plan~ sh~wing compliance, <br /> <br />The p~a~s will go on "HOLD" until such time that thes~ revisions are submitted <br />for rmview. The i~mms liste~ above are preliminary in nature. A complete <br />plan review will be %~repared when the items above have been r~molved. <br />Additional item~ may be re~ired depending on how the items abov~ are <br />resolved. <br /> <br />DeNS. Lb WOODL~Y <br />BUILDING OFFICIAL <br /> <br />file <br /> <br />"A~PROVED" only when this sheet is attached to plans <br /> <br /> <br />