Laserfiche WebLink
Iqar on Count <br /> <br /> OREGON <br />COMMUNITY DEVELOPMENT <br />DEPARTMENT <br /> <br />NOTICE OF DENIP~I <br /> <br />EVALUATION KEPORT FOR AN <br />ON-SITE SEWAGE DISPOSAL SYSTEM <br /> <br />July 7, 1994 <br /> <br />DAVID T. SHRABEL <br />C/O AAA SEPTIC SERVICE <br />P/O BOX 20811 <br />SALEM, OREGON~ 97325 <br /> <br />FILE <br /> <br />SUBJECT: <br /> <br />SITE #94-624, T:SS, R:2W, S:26B, T/L:2400 <br />SITE ADDRESS: 7450 75TH PLACE SE, AUMSVILLE, ORE 97325 <br /> <br />An evaluation has been made of the above described property proposed for <br />installation of an on-site sewage disposal system. As a result of that <br />investigation, it has been determined that the site specified on your applica- <br />tion does not qualify for a standard septic System or any of the alternative <br />systems. The conditions on the site do not meet the minimum requirements of <br />the Department of Environmental Quality On-Site Sewage Disposal Rules. These <br />rules ar~ specified in Oregon Administrative Rules, Chapter 340, Division 71, <br />Sections 100 through 600. Consequently, this site must be denied. <br /> <br />The principal reasons for denial of this site are related to shallow seasonal <br />water levels. The following paragraphs outline the specific reasons for this <br />denial. <br /> <br />WATER TABLES= <br /> 1. A water table, as indicated by conditions associated with satura- <br /> tion, was observed on the property as follows: <br /> ' a. Evidence of a ~emporary water table was observed at 8~8 to 10 <br /> inches below the ground surface. These measurements were to <br /> the depth of the soil mottling or to the actual depth of an <br /> observed water table. <br /> 2. The above conditions do not meet the minimum D.E.Q. rules pertain- <br /> ing to standard and alternative sewage systems. The minimu~ <br /> requirements ar~ listed below: <br /> a. A temporary uroundwater table cannot be less than 24 inches <br /> below the ground surface for installation of a ~tandard <br /> septic system or 12 i~inches for installation of any of the <br /> alternative systems. <br /> <br />It should be noted that this study was done only in the area proposed on your <br />application for on-site sewage disposal. Within the boundaries of your proper- <br />ty, it is possible that soil conditions in a different area of the property <br />may be different than those examined in the existing test pits. If you feel <br />that better soil conditions may exist in anothe~ area of the property, <br />additional test pits will be inspected with no additional charge. Prepare and <br />submit a new site plan showing the new area proposed for evaluation. Notify <br />this office of your request in writing and within ninety (90) days of the <br />initial site evaluation. <br /> <br /> <br />