Laserfiche WebLink
Marion County <br /> <br /> OREGON <br />COMMUNITY Dk~CELOPMEN'1' <br />DEPARTMENT <br /> <br />NOT~CE OF DF~/~T.,: <br /> <br />~VALUATION R~PORT FOR AN <br />ON-SITE SEWAGE DISPOSAL SYSTEM <br /> <br />February 28, 1994 <br /> <br />J. R. STEWAiqT EOF~ES <br />689 G~RLAND COURT NORTE <br />KEIZER~ OREGON 97303 <br /> <br />SUBJECT~ <br /> <br />SITE #94-624, T=SS, R:2W, S:26 <br />SITE ADDRESS~ 7450 75TM PLACE SE. AUMSVILLE, OR 97325 <br /> <br />An evaluation has been made of the above described property proposed for <br />installation of an on-site sewage disposal system. As a result of that <br />investigation, it has been determined that the site specified on your applica- <br />tion does not qualify for a standard septic system or any of the alternative <br />systems. The conditions on the site do not meet the minimum requirements of <br />the Department of Environmental Quality On-Site Sewage Disposal Rules. These <br />rules are specified in Oregon Administrative Rules, Chapter 340, Division 71, <br />Sections 100 through 600. Consequently, this site must be denied. <br /> <br />The principal reasons for denial of this site are related to shallow water <br />tables and limited, area. The following paragraphs outline the specific reasons <br />for this denial. <br /> <br />WATER TABLES~ <br /> 1. A water table, as indicated by conditions associated with satura- <br /> tion, was observed on the property as follows: <br /> a. Evidence of a permanent water table was observed at 14 to 32 <br /> inches below the ground ~urface. These measurements were to <br /> the depth of the soil mottling or to the actual depth of an <br /> observed water table. <br /> 2. The above conditions do not meet the minimum D.E.Q. rules pertain- <br /> ing to standard and alternative sewage systems. The minimum <br /> requirements are listed below: <br /> a. A permanent droundwater table cannot be less than 66 inches <br /> below the ground surface for installatio~ of a standard <br /> septic system or 30 inches for installation of any of the <br /> alternative systems. <br /> <br />It should be noted that this study was done only in the area proposed on your <br />application for on-site sewage disposa2L, within the boundaries of your proper- <br />ty~ it is possible that soil conditions in a different area of the property <br />may be different than those examined in the existing test pits. If you feel <br />that better soil conditions may exist in another area of the property, <br />additional test pits will be inspected with no additional charge. Prepare and <br />submit a new site plan showing the new area proposed for evaluation. Notify <br />this office of your request in writing and within ninety (90) days of the <br />initial site evaluation. <br /> <br />ADDITIONAL COMmeNTS: <br /> There might be some possibility to re-consider the area of the most <br />easterly test pit for an alternative sand filter system plus a full capping <br />fill. The single test pit does not confirm whether there is enough area for <br />considering the alternative systems. Additional test pits will be necessary <br />for farther evaluation. <br /> <br /> <br />