Laserfiche WebLink
April 5, 1994 <br /> <br />Pfeifer Homes <br /> <br />Established 1945 <br />Oregon Builder ~ff)0136 <br /> <br />622 N. Water St, - P,O. Box - SIIverton, OR 97381 <br /> <br /> Ph, (503) 873-6393 <br />FAX (503) 873-8858 I <br /> <br />Marion County Building Department <br />220 High Street NE <br />Salem, OR 97301 <br /> <br />Re: Kerr/Aumsville 720 Del Mar Dr, Pr# 53191 DP <br /> <br />Dear Sirs: <br /> <br />We have inadvertently included the wrong detail on oar permit drawings. The details in <br />question show the footings as 8" X 16" with rebar. <br /> <br />The correct footing size should be 6" X 12" with no rebar, i can assure you that the <br />calculations were completed using the smager size. And, therefore we request that the <br />"permitted" drawings be modified as such. Thank you, <br /> <br />Respectfully submitted, <br /> <br />Mark S, Ellingson, P.E. <br /> <br />ME:Ih (: <br /> <br />We listlen ............. We have ideas <br /> <br /> <br />