Laserfiche WebLink
Marion County <br /> <br /> OREGON <br />COMMUNITY DEVELOPMENT <br /> DEPARTMENT <br /> <br />DIRECTOR <br />Craig O. Luedeman STRUCTURAL PLANS REVIEW <br /> <br />BUILDING INSPECTION DATE: June 20, 1994 <br />(503) 588-5147 <br /> <br />pLANNING& SUBJECT: 14397 Keil Rd. NE, Aurora <br />(503) 5&g-5038 OWNER: Jack Hogan <br /> <br />BOARD O~ CONTROL NUMBER: 94-00776 <br />COMMIglONE~ PE~IT NUMBER ~ 53092 <br />Randall F~anke <br />GaryHe~r TYPE OF CONSTRUC~ONt V-N <br /> <br />ADMINISTRATIVE BUILDING CLASS: g-3 <br />Ken Ro~dybu~h <br /> <br />The plans for the above indicated project are acceptable as submitted <br />subjeot tO the following items noted below: <br /> <br />T~is is a Plan Review covering the construction of the above indicated new <br />building. Plans have been reviewed for compliance with the provisions of the <br />Oregon State Structural Specialty Code ('91 UBC) 1993 Edition. <br /> <br />This building was reviewed as a aircraft storage hanger only where no <br />repair work is performed as there are no restroom facility on the <br />property. <br /> <br />The building exceeds the floor area limits set forth in Table No. 5-C. <br />The floor areas specified in Section 505 may be increased where public <br />ways or yards adjoin the proposed construction on two or more sides. <br />(605) There are enough yards for a 100% increase in the allowable area. <br /> <br />Maintain 20 feet to property lines on all sides of the building as no <br />details for one-hour eEterior walls and protection of the openings were <br />indicated on the plans. (Table No. 5-A) <br /> <br />Floor surfaces shall be of noncombustible, nonabsorbent materials. <br />Floors shall drain to an approved oil separator or trap discharging to <br />sewers in accordance with the Pluming Code. <br /> <br />Floors may be surfaced or waterproofed with asphaltic paving materials <br />in areas where motor vehicles or airplanes are stored or operated. <br />(702(c)) <br /> <br />Approval of submitted plans is not an approval of omissions or oversights by <br />this office or of noncompliance with any applicable regulations of local <br />government. <br /> <br />This project may be subject to the architectural standards of the Americans <br />with Disabilities Act of 1990 (ADA). Issuance of a building permit does not <br />certify compliance with this Federal Statute. Copies of the guidelines and <br /> <br />Senator Building 220 High Street NE Salem, Oregon 9730]-3670 <br /> <br /> <br />