Laserfiche WebLink
DIRECTOR <br />Craig O, Lu~deman <br /> <br />BUILDING iNSPECTION <br />(503) 588-5147 <br /> <br />PLANNING & <br />ENFORCEMENT <br />{503) 588-5038 <br /> <br />BOARD OF <br />COMMISSIONERS <br />RandaU Franke <br />Gary Heer <br /> <br />ADMINISTRATIVE <br />Ken Roudybush <br /> <br />Marion County <br /> <br /> OREGON <br />COMMUNITY DEVELOPMENT <br />DEPARTMENT <br /> <br />PLAN REVIEW NOTICE <br /> <br />DATE: <br /> <br />March 29, 1994 <br /> <br />SUBJECT: <br /> <br />20727 Highway 99E NE~ Aurora <br />Lunch Room Modifications <br /> <br />OWNER: <br /> <br />Osegon Flowers Inc. <br /> <br />CONTROL NUMBER: <br />PERMIT NUMBER: <br /> <br />94-01148 <br />53788 <br /> <br />TYPE OF CONSTRUCTION~ 5-N <br /> <br />BUILDING CLASS~ <br /> <br />S-2 / A-3 (O.L. 60 ccc.) <br />(Total= 8,400 sq. ft. w/ 3 yards) <br /> <br />The plans for the above indicated project are acceptable as submitted <br />subject to the following items noted below: <br /> <br />This is a plan review covering the modifications improve exiting and occupancy <br />separation non-code complying construction to the above existing building. <br />The modifications have been'discussed with the building official. The details <br />shown have been accepted as providing a reasonable degree of safety while not <br />necessarily in full compliance with the current code. This review is based on <br />the regulations of the Oregon State Structural Specialty Code ('91 UBC) 1993 <br />Edition. <br /> <br />This review is not intended to prohibit the building inspector from requesting <br />an evaluation of the acceptability of existing structural members that may <br />appear to be unsafe. Existing construction not specifically detailed in the <br />plans and structural calculations is beyond the scope of this review. <br /> <br />Plans should indicate the land,lBS on each side of stair doors is not <br />more than 1 inch lower than the threshold of the doorway. Sec. 3304(i) <br /> <br />Exit doors shall be openable from the inside without the use of a key or <br />any special knowledge or effort. Manually operated edge or surface <br />bolts are prohibited. (3304(c)) <br /> <br />When two or more exits are required from a room o~ area, exit signs <br />shall be installed at the required exits from the room or area and where <br />otherwise necessary to clearly indicate the direction of egress. <br />(3314(a)) <br /> <br />It has been determined that an occupancy separation is not necessary <br />between the greenhouse and the remaining portions of the buildings. <br /> <br />Approval of submitted plans is not an approval of omissions or oversights by <br />this office or of noncompliance with any applicable regulations of local <br />government. <br /> <br />Senator Building 220 High Street NE Salem, Oregon 97301-3670 <br /> <br /> <br />