My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1284558
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
94-XXXXX
>
Permit - 1284558
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2011 2:04:17 PM
Creation date
9/3/2003 4:25:40 PM
Metadata
Fields
Template:
Permits
Permit Address
9610 MILL CREEK RD SE
Permit City
Aumsville
Permit Number
94-00311
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Marion County <br /> <br /> OREGON <br />COMMUNITY DEVELOPMENT <br />DEPARTMENT <br /> <br />DIRECTOR <br />Craig O, Luedeman <br /> <br />BUILDING INSPECTION <br />(503) 5~-5147 <br /> <br />PLANNING& <br />ENFORCI~MENT <br />(503) 500-5030 <br /> <br />'BOARD OF <br />COMMISSIONERS <br />Ra~daU ~ranke <br />Gary Heer <br />~arr Pear~ine <br /> <br />ADMINISTRATIVE <br />OFFICER <br />Ken Roudybush <br /> <br />DATE: <br /> <br />SUBJECT: <br /> <br />OWNER: <br /> <br />CONTROL NUMBER; <br />BUILDING PEP~MIT: <br /> <br />TXPE OF CONSTRUCTION: <br />BUILDING CLASS: <br /> <br />STRUCTURAL PLANS P~EVIEW <br /> <br /> January 18, 1994 <br /> <br /> 9610 Mill Creek Road SE <br /> <br /> ~ktron Industries <br /> <br /> 93-3737 <br /> 51S66 <br /> <br /> 5-N <br /> <br />The plans for the above indicated project are acceptable as submitted <br />subject to the following items noted below: <br /> <br />This is a plan review covering the alterations to the above existing building. <br />This review is based on the regulations of the Oregon State Structural Specialty <br />code ('91 UBC) 1993 Edition. <br /> <br />Office buildings, retail stores, warehouses and factories or workshops <br />using materials not highly flan~nable or combustible are classified as <br />G~oup B Division 20ooupanoies (B-2). Based on the limited information <br />submitted with the plans, this building has been classed as a <br />Occupancy. The use or storage of highly flammable or combustible <br />materials would cause the oscupansy classification to be changed and <br />additional code requirements may be necessary. Contact Marion County <br />Building Inspection if this occupancy classification is not appropriate to <br />your intended use of the facility. (701) <br /> <br />The powder coating booth shall be in accordance with section 45 Division <br />VI of the Uniform Fire Code. <br /> <br />Portable fire extinguishers shall b~ provided and installed as required by <br />applicable standards and as directed by the authority having jurisdiction. <br />(U.F.C. 10.505; U.F.C. Std. No. 10-1) <br /> <br />Approval of submitted plans is not an approval of omissions or oversights by this <br />office or of noncompliance with any applicable regulations of local government. <br /> <br />This project may be subject to the architectural standards of the Americans with <br />Disabilities Act of 1990 (ADA). Issuance of a building permit does not certify <br />compliance with this Federal Statute. Copies of the guidelines and information <br />concerning the ADA may be obtained from the Architectural and Transportation <br />Barriers Compliance Board, 1-202-653-7834 (Voice/TDD) or 1-800 USA-ABLE. Failure <br />to comply with the ADA may result in Federal Fines and penalties. <br /> <br />Senator Building 220 High Street N~: Salem, Oregon 97301-3670 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.