Laserfiche WebLink
11631 STEINKAMP RD SE, AUM~VILLE <br />January 2~, ~994 <br />Page 2 <br /> <br />54. <br /> <br />Provide screened attic vents with a net free area of 1/150 of the attic <br />area (or 1/300 if half is along eaves and the other half in the upper <br />portion). (R-707) <br /> <br />62. <br /> <br />Roof trusses are required to be designed by an Oregon registered <br />Engineer or A~¢hitect. For trusses manufactured by an approved <br />fabrication plant, have the design and layout drawings available at the <br />construction site for the framing inspection. All job site cutting or <br />modification of the roof trusses shall be clearly shown in the <br />engineer's design calculations and drawings. If trusses are to be built <br />at the job site, submit the engineer's design and construction plans to <br />the Marion County Building Department prior to start of construction and <br />have the approved drawings available at the site for the framing <br />inspection. <br /> <br />65. Fireplace and chimney construction shall conform to chapter 9. <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />FP <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />