Laserfiche WebLink
February 2, 1993 <br /> <br />APPLICANT: <br />SITE NUMBER: <br /> <br />STANDARD SYSTEM CONSTRUCTION DETAIL SHEET <br /> <br />CALIFORNIA iNVESTORS CORP. <br />93-394 <br /> <br /> Your site has been found suitable for a STANDARD ON-SITE $~WAGE DISPOSAL <br />SYSTEM. The following construction specifications shall apply to the installa- <br />tion of your septic system. <br /> <br /> 1. The septic tank shall have a minimum liquid capacity of 1000 <br /> gallons. <br /> <br />The projected daily sewage flow for this project is calculated at <br />450 qal~g~s per day. Based on soil conditions observed on this <br />site, the disposal field will be sized at 50 lineal feet Der 150 <br />qallons of projected daily sewage flow. A minimum of 150 liDeal <br />~e~t of disposal field will be required for your proposed develop- <br />ment. The disposal trenches are constructed two (2) feet wide and <br />On minimum ten (10) foot centers and with no line exceeding 125 <br />feet in length. The trenches and perforated pipe are installed <br />level (±1") and contoured to follow the natural ground surface. <br /> <br />The disposal field shall be constructed with serial distribution <br />with a minimum trench depth of 24 inches and a maximum trench <br />depth of 36 inches. There must be at least 12 inches of backfill <br />over the top of the gravel, measured from the natural ground <br />surface. <br /> <br /> This approval is site specific to the area tested and the septic system <br />must be located in the i~mediate area of the test pits unless otherwise autho- <br />rized by this office. A new site evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS: <br /> Construct the drainfields within the immediate area of the soil test <br /> pits. A per-construction field stakeout is recommended to establish the <br /> location of the individual drainfield lines for both drainfields prior <br /> to any excavation. An alternative sand filter system might be necessary <br /> for future repairs because of limited space and the possibility of a cut <br /> bank more than thirty inches tall at the lower (southerly) property <br /> boundary. Observe all normal setback/separation distances. Refer to the <br /> enclosed setback list which outlines minimum setbacks between septic <br /> systems and other features. <br /> <br />~HIE Is NOT A PERMIT TO INSTALL ~HE SEPTIC SYSTEM. DO,NOT INSTALL THE SYST~ <br />UNTIL A VALID PERMIT HAS BEEN ISSUED BY TEIS OFFICE. <br /> <br /> <br />