iNS'£ALLAT'ION OF 1,000 GALLON AND 1,500 GALLON SEPTIC <br />TANKS AND DOSING-SEPTIC TANKS <br /> <br />ALL TANKS must be set level on undisturbed earth or sand bedding <br />to prevent settlelng. Use 3/4" Kens Seal ~£ or approwed equal <br />to seal all field joints. If Joints must be disturbed, replace <br />all old Kent Seal wi~h new material. If Kent Seal is unavailable, <br />an acceptable substlSute is groat made with hydrolic cement <br />mixed in the specified proportions. <br /> <br />ALL dosing-septic tanks should be water Sested when installed, <br />before back-filling and before hooking up to sewer pipe, So <br />test for leakage and ~o prevent floating in hlgh water areas. <br /> <br />~'LOAT level controls in 1,000 gallon dosing-septic tank are to <br />be see as follows: <br /> <br /> With regard to the pump controls, a 4 inch cycle is required for all new <br /> single family dwelling building sites. This is a minimum criteria for <br /> standard systems, but a maximum criteria for those ~ystems utilizing <br /> pressurized d~stribution. Based upon the original engineering ~pecifi- <br /> cations for the dosing~septic tank, the off-level can be no greater than <br />~-41.5 inches from the bottom of the tank~ Measuring from the top exteri- <br /> or of the tank, the off-level would then measure 21.5 inches. This way, <br /> as according to DEQ rules, the tank would have a remaining capacity <br /> after*cycle of 900 gallons~ With a 4 inch cycle, the pump on-level <br /> would then measure 17.5 inches, again measured from the top exterior <br /> edge of the tank. With regard to the alarm, which has.been the compo- <br /> nent of the p~eset controls found to be out of coordination, for reasons <br /> of providing some level of storage volume within the tank, an operatin~ <br /> level of 15 inches has been established. In this way, a zone between <br /> the pump on-level and the alarm of 1.5 inches can be maintained and at <br /> least 3 inches or approximately 66 gallon~ of storage volume can be <br /> provided upon alarm signal. To make things simpler for the construction <br /> ~ndustry, we have b~en operating on the following measurements; <br /> <br />Pump Off - 21 inches; Pump On - 17 inches, Alarm <br /> <br />~ll of which are measured from a straight edge, laid across the <br />exterior of the tank. where the Orenco b%~cket Js umed, we have <br />factor of 1 inch to account for the raised edge of the bucket which <br />would increase each of these measurements accordingly. <br /> <br />Measurements for 1,500 gallon tank from top of tank are the same, <br />only the remaining capacity changes.* <br /> <br />Note to home owners: ALL tanks should be pumped every five (5) <br />years for ~he average famlly of five (5). This ls to prevent <br />serious sludge damage to the leach fleld~. <br /> <br /> <br />