My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1278972
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
92-XXXXX
>
Permit - 1278972
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2011 10:42:35 AM
Creation date
9/3/2003 1:40:48 PM
Metadata
Fields
Template:
Permits
Permit Address
270 SANTIAM AV W
Permit City
Detroit
Permit Number
92-01875
Parcel Number
105E02DA04900
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Anl '-'" <br />WASTE DISPOSAL SYSTEMS MARION COUNI¥ <br />1242 31St Ct, N.W. BUiLDiNG tNSP[,C] g i <br />Salem, OR 97304 <br />364-7470 <br /> April ~7, 1992 <br /> <br />Lee Grimes <br />Marion County Building Dept. <br />220 High St. N.E, <br />Salem, Or. 97301 <br /> <br />~e: Drainfield layout <br /> <br />and design. <br /> <br />William Tucker application <br />lots 17 & 18 Block 9 <br />· Hammond Addition to Detroit. <br /> <br />Attached you <br />proposed site <br />primarily for <br />to January 1, <br /> <br />will find a drainfield layout plan for Mr. Tuckers <br />in Detroit. This lot is proposed to be used <br />recreational purposes. This lot was created prior <br />1974 and Mr. Tucker can provide a copy of the deed <br /> <br />to verify this. <br /> I have contacted Kevin Hill and he should have test holes on <br />the site dug by now but this will be confirmed. <br />The drainfield lines have been staked out on the property as <br />shown in the plot plan and the elevations relate to the water <br />valve box by the N.W. property corner. <br /> I have calculated that the drainfield requirement for the <br />initial system should be approximately 134' These calculations <br />are as follows: <br /> Length = 4 X standard trench/3 + rock depth under pipe (2). <br /> Estimate soil in group B with depth of 36' to 48" which <br /> would require 100' per bedroom. <br /> 4 X 100'/3 + 1.5 (2)=400/6.00 = 66.7' per 150 gal. <br /> flow. This should be approximately 134' required for the <br /> primary system. <br /> A sand filter/seepage trench repair system is proposed and <br />using the above formula with 45' used for the standard drainfield <br />portion of the equation, this should calculate to approximately <br />30' of trench required per 150 gallons or room for a total of 60 <br />lineal feet of replacement area. <br /> Please review these calculations and the onsite stakeout and <br />let me know if you need anything else. The above is based on <br />soil conditions that have been found on other lots in the area <br />and I hope they prove to be accurate. <br /> <br /> <br />