My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1278415
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
92-XXXXX
>
Permit - 1278415
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2010 1:36:57 PM
Creation date
9/3/2003 1:25:33 PM
Metadata
Fields
Template:
Permits
Permit Address
9804 MILL CREEK RD SE
Permit City
Aumsville
Permit Number
92-02403
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Marion County <br /> <br /> OREGON <br />COMMUNITY DEVELOPMENT <br /> DEPARTMENT <br /> <br />DIRI~CTOR <br />Craig O. Luedemar~ <br /> <br />BUILDING INf, PECTION <br />(503) 588-5147 <br /> <br />pLANNING & <br />[NEO ~',CEMI~.NT <br />(503) 588-5038 <br /> <br />BOARD OF <br />COMMISSIONERS <br />Randall Franke <br />Gary Heer' <br />Mary Pearmine <br /> <br />ADMINISTRATIVE <br />OFFICER <br />Ken Roudybush <br /> <br />STRUCTURAL pLANS REVIEW <br /> <br />DATE= <br /> <br />SUBJECT: <br /> <br />August 3, 1992 <br /> <br />9804 Mill Creek Rd. S.E., Aumsville <br /> <br />OWNER= <br /> <br />Klein, Larry <br /> <br />SITE NUMBENt <br /> <br />92-02403 <br /> <br />TYPE OF CONSTRUCTION: V-N <br /> <br />BUILDING CLASS: <br /> <br />B-2 <br /> <br />The plans for the above indicated project are acceptable as submitted <br />subject to the following items noted below= <br /> <br />This plan review covers a 660 equate foot addition to an exieting 316B <br />square foot building giving a total area of 3828 square feet. Yards are <br />as follows; North, 146 to Hwy 22. West, 50' to existing shop. South, <br />60'+. East, 60'+. <br /> <br />This is a Plan Review covering the construction of the above addition to <br />the existing building. This review is for compliance with the provisions <br />of the Oregon state Structural Specialty code (UBC) 1990 Edition. This <br />review is not intended to prohibit the building inspector from requesting <br />an evaluation of the acceptability of existing structural members that may <br />appear to be unsafe. Existing construction not specifically detailed in <br />the plans and structural calculations is beyond the scope of this review. <br /> <br />Plans should indicate the floor or landing on each side of doors is not <br />more than i inch lower than the threshold of the doorway. Sec. 3304(f) <br /> <br />Hardware for all exit doors required for egress is required to be of a <br />simple type having no provision for locking against egress, and having an <br />obvious method of operation. Flush bolts other than listed automatic are <br />not acceptable. Sec. 3304(c), see Exception. <br /> <br />Portable fire extinguisher shall be provided and installed as required by <br />applicable standards and as directed by the authority having jurisdiction. <br />(U.F.C. 10.303; U.F.C. Std. No. 10-1) <br /> <br /> Fireblocking shall be installed in the following locations. <br />a) In concealed spaces of stud walls and partitions, including furred <br /> spaces, so placed that the maximum dimension of any concealed space <br /> is not over 10-feet, and at the ceiling and floor levels. <br />b) At all interconnections between concealed vertical and horizontal <br /> spaces such as occur at soffits, drop ceilings and cove ceilings. <br />c) In openings around vents, pipes, ducts, chimneys, fireplaces and <br /> similar openings which afford a passage for fire at ceiling and <br /> floor levels, with noncombustible material. (2516(f)2) <br /> <br />Senator Building 220 High Street NE - Salem, Oregon 97301-3670 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.