My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1277569
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
92-XXXXX
>
Permit - 1277569
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2011 12:00:56 PM
Creation date
9/3/2003 12:57:01 PM
Metadata
Fields
Template:
Permits
Permit Address
20701 OLMSTEAD RD NE
Permit City
Aurora
Permit Number
92-01442
Parcel Number
041W18C 01100
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
20. <br /> <br />22. <br /> <br />24. <br /> <br />25. <br /> <br />26. <br /> <br />Porches, balconies or raised <br />floor surfaces located more <br />than 30 in. above the floor or <br />grade shall have guardrails not <br />less than 36 in. in hr. <br />Required guardrails shall have <br />intermediate rails or ornamen- <br />tal closures which will not <br />allow passage of an object 6 <br />in. or more in diameter. <br />214.2 <br /> <br />Smoke detectors shall be <br />installed outside of each <br />separate sleeping area in the <br />immediate vicinity of the <br />bedrooms and on each additional <br />story of the dwelling including <br />basements. In dwelling units <br />with split levels, a smoke <br />detector need be installed only <br />on the upper level, provided <br />the lower level is less than <br />one full story below the upper <br />level, except that if there is <br />a door between levels then a <br />detector is required on each <br />level. All detectors shall be <br />connected to a sounding device <br />or other detectors to provide, <br />when actuated, an alarm which <br />will be audible in all sleeping <br />areas. R-215.1 <br /> <br />In new construction, required <br />smoke detectors shall receive <br />their primary power from the <br />building wiring. Smoke detec- <br />tors may be battery operated <br />when installed in existing <br />buildings. R-215.2 <br /> <br />Firestopping shall be provided <br />in the following locations: in <br />concealed spaces of stud walls <br />at the ceiling, floors,soffits, <br />drop ceilings, between stair <br />stringers and at openings <br />around vents, pipes, ducts, <br />chimneys and fireplaces at <br />ceiling an~ floor spaces. R- <br />402.7 <br /> <br />Foundation cripple walls shall <br />be framed of studs with a min. <br />length of 14 in. or shall be <br />framed of solid blocking. R- <br />402.9 <br /> <br />The area within the foundation <br />~walls shall have all vegeta- <br />tion, top soil and foreign <br />material removed. R-603.2 <br /> <br />Rafters shall be nailed to <br />ceiling joists to form a con- <br />tinuous tie between exterior <br />walls where joist are parallel <br />to the rafters. Where not <br />parallel, rafters shall be tied <br />with a rafter tie, located at <br />or near the plate as practical. <br />Rafter ties shall be spaced not <br />more than 4 feet on center. <br /> <br /> 2. / <br /> <br />33. <br />34. <br /> <br />35. <br /> <br />3~. <br /> <br />less in depth than the cut arid <br />of the rafter. At all valleys <br />and hips there shall be a <br />valley or hip rafter not less <br />than 2 in. nominal thickness <br />and not less in depth than the <br />cut end of the rafter. R-702.2 <br /> <br />When the roof pitch is less <br />than 3 in 12, members support- <br />lng rafters and ceiling ]c~st, <br />such as ridge beams, hzps sn~ <br />valleys, shall be designed s~ <br />beams. R-702.3 <br /> <br />Wood trusses shall be designed <br />in accordance with approved <br />engineering practice. Trusses <br />shall be braced according tc <br />their appropriate engineered <br />design. Truss members shall <br />not be cut or altered un~ess <br />so designed.R-702.9 <br /> <br />All plywood, when designed to <br />be exposed in outdoor applica- <br />tions shall be of an exterior <br />type, except that plywood roof <br />sheathing exposed to the <br />underside may be of interior' <br />type with exterior glue. ~- <br />703.1 <br /> <br />Provide screened attic ve~'~ts <br />with a net free area of 1/].50 <br />of the attic area (or 1/300 if <br />half is along eaves and the <br />other half in the upper <br />portion). R-707 <br /> <br />A readily accessible atsic <br />access framed opening not less <br />than 22 in. by 30 in. shall be <br />provided. R-708 <br /> <br />Fireplace and chimney con- <br />struction shall conform to <br />chapter 9. <br /> <br />INSULATION REQUIREMENTS : <br />Buildings with high-efficiency <br />heating equipment shall be <br />insulated as follow: ceiling <br />R-30 (roof/ceiling assemblies <br />in which has a slope of 3 in <br />12 or greater, may be R-19), <br />walls R-11, underfloors <br />other heating systems, ceiling <br />R-38 (vaulted ceiling R-19/ <br />walls R-19 and under floor <br />19. <br /> <br />Elements of appliances which <br />create a glow, spark or flame <br />shall be located a min. of 18 <br />in. above garage floor. M- <br />1114 <br /> <br />Appliances subject to mechani- <br />cal damage shall be guarded <br />a protective barrier. <br /> <br />27. Ridge board shall be at least 1 <br /> inch nominal thickness and not <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.