My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1276187
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Old Files 5
>
Permit - 1276187
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2011 10:19:06 AM
Creation date
9/3/2003 12:14:05 PM
Metadata
Fields
Template:
Permits
Permit Address
905 8TH ST
Permit City
Aumsville
Permit Type
Permit
Permit Site Number
13887
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
20. <br /> <br />Porches, balconies or raised <br />floor surfaces located more <br />than 30 in. above the floor or <br />grade shall have guardrails not <br />less than 36 in. in hr. <br />Required guardra~ls shall have <br />~ntermediate rails or ornamen- <br />tal closures which will not <br />allow passage of an object 6 <br />in. or more in diameter. R- <br />214.2 <br /> <br />2 l~,~S-m o k e detectors shall be <br /> · nstal led outside of each <br /> separate sleeping area in the <br /> immediate vicinity of the <br /> bedrooms and on each additional <br /> story of the dwelling including <br /> basements. In dwelling units <br /> with split levels, a smoke <br /> detector need be installed only <br /> on the upper level, provided <br /> the lower level is less than <br /> one full story below the upper <br /> level, except that if there is <br /> a door between levels then a <br /> detector is required on each <br /> level. All detectors shall be <br /> connected to a sounding device <br /> or other detectors to provide, <br /> when actuated, an alarm which <br /> wlll be audible in all sleeping <br /> areas. R-215.1 <br /> <br />22. <br /> <br />In new constructlon, required <br />smoke detectors shall receive <br />their primary power from the <br />building wiring. Smoke detec- <br />tors may be battery operated <br />when installed in existing <br />buildings, R-215.2 <br /> <br />23. <br /> <br />Firestopping shall be provided <br />in the following locations: in <br />concealed spaces of stud walls <br />at the ceiling, floors,soffits, <br />drop ceilings, between stair <br />stringers and at openings <br />around vents, pipes, ducts, <br />chimneys and fireplaces at <br />ceiling and floor spaces. R- <br />402.7 <br /> <br />24. <br /> <br />Foundation cripple walls shall <br />be framed of studs with a min. <br />length of 14 in. or shall be <br />framed of solid blocking. <br />402.9 <br /> <br />25, <br /> <br />26. <br /> <br />The area within the foundation <br />walls shall have all vegeta- <br />tion, top soil and foreign <br />material removed. R-603.2 <br /> <br />Rafters shall be nailed to <br />ceilln9 joists to form a con~ <br />tinuous tie between exterior <br />walls where joist are parallel <br />to the rafters. Where not <br />parallel, rafters, shall be tied <br />with a rafter tie, located at <br />or near the plate as practical. <br />Rafter ties shall be spaced not <br />more than 4 feet on center. <br /> <br />27. Ridge board shall be at least 1 <br /> inch nominal thickness and not <br /> <br />less in depth than the cut <br />of the rafter. At all valleys <br />and hips there shall be a <br />valley or hip rafter not less <br />than 2 in. nominal thickness: <br />arid not less in depth than the <br />cut end of the rafter. R-702.2 <br /> <br />When the roof pxtch is less <br />than 3 in 12, memOers suppo:t- <br />lng rafters and ce~l!n~ ]~isL~ <br />such as ridge beams, hips a-~ <br />valleys, shall be des~qn~d s~ <br />beams. R-702.3 <br /> <br />Wood trusses shall be designed <br />in accordance with appro'ued <br />engineering practlce. Trusses <br />shall be braced according ~c <br />their appropriate englnecred <br />design. Truss members shall <br />not b~ cut or altered unless <br />so designed. R-702.9 <br /> <br />All plywood, when designed <br /> <br />be exposed in outdoor applica- <br />tions shall be of an exterior <br />type, except that plywood roof <br />sheathing exposed to the <br />underside may be of inter,or <br />type w~th exterior glue. R- <br />703.1 <br /> <br />Provide screened attic <br /> <br />with a net free area of 1/1S0 <br />of the attic area (or 1/300 if <br />half is along eaves and %ne <br />other half in t~%e upper <br />portion). R-707 <br /> <br />3~-~-eadily accessiole attic <br /> access framed opening not less <br /> than 22 in. by 30 la. shall De <br /> provided. R-708 <br /> <br />33. Fireplace and chimney con- <br /> struction shall conform to <br /> chapter 9. <br /> <br />34. INSULATION REQUIREMENTS: <br /> Buildings with hlgh-efficlency <br /> heating equipment shall be <br /> insulated as follow: ceiling <br /> R-30 (roof/ceiling assemblies <br /> in which has a slope of 3 in <br /> 12 or greater, may be R-19), <br /> walls R-11, underfloors R-19, <br /> other heating ~ystems, celliag <br /> R-38 (vaulted ceiling R-19J <br /> walls R-19 and under floor R- <br /> 19. <br /> <br /> 5. Elements of appliances which <br /> create a glow, spark or flame <br /> shall be located a min. of 18 <br /> in. above garage floor. M- <br /> 1114 <br /> <br />36. Appliances subject to mechani- <br /> cal damage shall be guarded Dy <br /> a protective barrier. M-1114 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.