My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1275364
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Road Names
>
Permit - 1275364
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2012 8:26:32 AM
Creation date
9/3/2003 11:56:31 AM
Metadata
Fields
Template:
Permits
Permit Address
13058 DONALD RD NE
Permit City
Aurora
Parcel Number
041W15D 01700
Permit Type
Permit
Permit Site Number
14584
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NOW DETERMINE k2 FROM LUTTRELL'S FORMULA <br /> Et 29/000,000'0.0165 <br /> <br /> [2(l+V) g/p+k2/(144"*0.0165)^2] [2'(1+0-3)'1.2+k2/(144'.0165)~2] <br /> <br />k2 value = 2,542.78 <br /> <br />THE ROOF SLOPE LENGTH FROM CENTER OF THE EAVE GIRT TO CENTER OF RIDGE <br />PURLIN, L= 148.43 INCHES <br /> <br /> C = .............................. = 1,120.50 <br /> [2*(l+.3)*l.2+k2/(L*.0165)~2] <br /> <br />Ch=C * (COS A)^2 * 2= 2,109.17 <br /> <br />DETERMINE THE RELATIVE STIFFNESS OF FRAME TO ROOF <br /> k/Ch = 0.1388 <br /> <br />DETERMINE mD AND mS REDUCTION FACTORS FROM TABLES I AND 2 <br />(GEEREMEDHIN PGS. 1366-1367) BASED UPON THIS STRUCTURE HAVING <br />5 FRAMES INCLUDING THE ENDWALLS. <br /> <br />mD= 0.9351 mS= 0.4672 <br /> <br />STEP #4: CALCULATE THE RESIATANCE FORCE TO SIDESWAY AND SHEAR FORCE <br />IN THE ROOF CLADDING. <br />RESISTANCE FORCE TO SIDEWAY = mD * ROLLER REACTION (from step#l) <br /> 0.93S1 * 737.54 = 689.64 <br />ROOF CLADDING SHEAR FORCE = ms * ROLLER REACTION <br /> 0.4672 * 737.54 = 344.62 <br /> <br />STEP#5 ~ DISTRIBUTE THE RESISTANCE FORCE TO SIDESWAY EQUALLY AT THE <br />TOP CHORD NODES OPPOSITE THE WIND LOADING ON THE WALLS. <br /> NUMBERS OF NODES~ 5 <br />RESISTANCE FORCE/No. of NODES= 137.93 lbs./EACH NODE <br /> <br />THE MAXIMUM COMBINED STRESSES INTERACTION VALUE= <br /> 0.69 <1.0 <br />THEREFORE USE 6x6 HFIR ~2 is O.K. <br /> <br />STEP ~6= CHECK SHEAR IN ROOFING NEAR ENDWALLS. <br />ROOF CLADDING SHEAR FORCE (STEP #4)/BUILDING WIDTH MUST BE LESS OR <br />EQUAL TO THE ADJUSTED SHEAR (V) FROM STEP #3 ADJUSTED FOR LOAD <br />DURATION (1.3333) <br /> 344.62 / 24.00 = 14.36 plf. <br /> 14.36 < (87.92'1.3333)= 117.22 <br /> 14.36 < 117.22 <br /> <br />CHECK SEEAR TRANSFERRED TO ENDWALL DIAPHGRAM. <br />ROOF CLADDING SHEAR FORCE (STEP ~4)/BUILDING WIDTH LESS DOOR <br />OPENINGS MUST BE LESS OR EQUAL TO usEABLE SHEAR FROM STEP <br />ADJUSTED FOR THE ON CENTER SPACING OF THE ENDWALL GIRTS ADJUSTED FOR <br />LOAD DURATION (1.3333) <br />24~END -12'DOOR(s)= 12.00 fT. USEABLE <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.