Laserfiche WebLink
MARION COUNTY <br />DEPT· OF ENVIRONMENTAL SERVICES <br /> <br /> CRAIG O. LU]~DP-MAN <br /> Director <br />Planning .588-5038 <br />Building Inspection .q88-5147 <br />Risk Manag,zment 58~-5294 <br /> <br />Senator Building * 220 High Street NE * Second Floor o Salem~ Oregon 97301-3670 <br /> <br />September 24, 1986 <br /> <br />TO: <br /> <br />FROM: <br /> <br />SUBJECT: <br /> <br />ADDRESS: <br /> <br />Craig Luedeman <br /> <br />Jim Trussell~ <br />Jay Erickson, Pole <br /> <br />100 Tumble Street, <br /> <br />building <br />Detroit <br /> <br />Contacted Jay Erickson explaining to hira that his truss <br />spanning 30' would have to be designed trusses with <br />calculations or redesign the building in accordance with the <br />conventional framing requirements. <br /> <br />Jay Erickson resubmitted plans with trusses spanning 15' I <br />explained to him that I could not accept his trusses without <br />calculations. I could only accept conventional framing <br />requirements for his trusses he submitted. A 2 X 12 spanning <br />15' with subperlins 24" o.c. spatlning 12' would not meet the <br />requirements. <br /> <br />Re-contacted Mr. Erickson the next day and explained that if <br />he reduced the span of his 2 X 12 to 9' or less that the <br />plans would be acceptable. He agreed to add struts from each <br />post to his 2 X 12 'to reduce the span to 9' or less which is <br />acceptable under conventional framing requirements. <br /> <br /> <br />