My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1272567
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Old Files 5
>
Permit - 1272567
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2011 9:27:50 AM
Creation date
9/3/2003 10:39:33 AM
Metadata
Fields
Template:
Permits
Permit Address
745 MICHAEL WY
Permit City
Aumsville
Permit Type
Permit
Permit Site Number
11453
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
20. Porches, balconies Or raised <br /> floor surfaces located more <br /> than 30 in. above the floor or <br /> grade shall have guardrails not <br /> less khan 36 in. in <br /> Required guardrails shall have <br /> intermediate rails or ornamen- <br /> tal closures which will not <br /> allow passage of an object 6 <br /> in. or more in diameter. <br /> 214.2 <br />~ Smoke detectors shall be <br />~ Installed outside of each <br />separate sleeping area in the <br />mmmediate vicinity of the <br />bedrooms and on each additional <br />story of the dwelling including <br />basements. In dwelling units <br />with split levels, a smoke <br />detector need be installed only <br />on the uppe~ level, provided <br />the lower level is lees than <br />one full story below the upper <br />level, except th%t if there is <br />a door between levels then a <br />detector is required on each <br />level. All detectors shall be <br />connected to e ~ounding device <br />or other detectors to provide, <br />when actuated~ an alarm which <br />will be audible in all sleeping <br />areas. R-215.] <br /> <br /> 22. In new constructlon~ required <br /> smoke detectors shall receive <br /> their primary power from the <br /> building wiring. Smoke detec- <br /> tors may be battery operated <br /> when Installed in existing <br /> buildings, R-215.2 <br /> <br /> F~restopping snell be provided <br /> in the following locations: in <br /> <br />concealed spacee of stud walls <br />at the ceiling, floors,soffits, <br />drop celllngs, between stair <br />stringers and at openings <br />around vents, pipes, ducts, <br />chimneys and fireplaces at <br />ceiling and floor spaces. <br />402.7 <br /> <br />24. <br /> <br />Foundation cripple walls shall <br />be framed of studs with a min. <br />length of 14 in~' or shall be <br />framed of solid blocking. R- <br /> <br />less ~n depth than the cut end <br />of the rafter. At all valleys <br />and hips there shall be a <br />valley or hip rafter not less <br />than 2 in. nominal thickness <br />and not less in depth than the <br />cut end of the rafter. R-702.2 <br /> <br />28. <br /> <br />When the roof pitch zs less <br />than 3 in 12, members support- <br />ing rafters and ceiling 3ozst, <br />such as ridge beams, h~ps and <br />valleys, shall be designed as <br />beams. R-702.3 <br /> <br />Wood trusses shall be designed <br />in accordance with approved <br />engineering practice. Trusses <br />shall be braced according ~o <br />their appropriate engineered <br />design. Truss members shall <br />not be cut or altered unless <br />so designed. R-702.9 <br /> <br />Ail plywood, when designed to <br /> <br />be exposed in outdoor applica- <br />tions shall be of an exterior <br />type, except that plywood roof <br />sheathing exposed to the <br />undereide may be of interior <br />type with exterior glue. R- <br />703.1 <br /> <br />Provide ecreened attic vents <br />with a net free area of 1/1~0 <br />of the attic area (or 1/300 ~f <br />half is along eaves and the <br />other half in the up~er <br />portion}. R~707 <br /> <br />A readily accessible attic <br />access framed opening not less <br />than 22 in. by 30 in. shall be <br />prov£ded. R~708 <br /> <br />34. <br /> <br />Fireplace and chimney con- <br />struction shall conform to <br />chapter 9. <br /> <br />INSULATION REQUIREMENTS: <br />Buildings with high-efficiency <br />he~ting equipment shall be <br />insulated as follow: ceiling <br />R-30 (roof/ceiling assemblies <br />in which has a slope of 3 in <br />12 or greater, may be R-19), <br />walls R-ii, underfloors R-19, <br /> <br /> 402.9 <br /> <br />25. The area within the foundation <br /> walls shall have all vegeta- <br /> tion, top soil and foreign <br /> material removed. R-603.2 <br /> <br />26. Rafters shall be nailed to <br /> ceiling joists to form a con- <br /> tinuuus tie between exterior <br /> walls where joist are parallel <br /> to the rafters. Where not <br /> parallel, rafters shall be tied <br /> wi~h a rafter tie, located at <br /> or near the plate as practical. <br /> Rafter ties shall be spaced not <br /> more than 4 feet on center. <br /> <br /> Ridge board shall be at least 1 <br /> inch nominal thickness and ~ot <br /> <br /> other heating systems, telling <br /> R-38 (vaulted ceiling R-19) <br /> walls R-19 and under floor R- <br /> <br />35. Elements of appliances which <br /> create a glow, spark or flame <br /> shall be located a min. of 18 <br /> in. above garage floor. M- <br /> <br />36. Appliances subject to mechani- <br /> cal damage shall be guarded by <br /> a protective barrier. M-1114 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.