Laserfiche WebLink
PROJECT <br /> <br />Santiam GoLf Course's InC. <br /> <br />LO~ATION; }I/ghway 22 and ~$erket Road 85 / <br /> (~, O, Box lit, ~Ca~C~) ,' <br /> <br />Land Zone P-5 Fire Zone <br />Area of B~ldiu~ ~572 A~able area (basic) <br /> ,~ Zone ~3 60~ <br /> <br /> 1. Provide windows 'equal in area to I/Sth of th~ floor area of thc room involved. <br /> ,R~qu/red ares go be'50lto~ab~, :-og a ~C~ V~atl~ sy~t~ Capable of <br /> <br />~ ~on-~sorbent ~tarial. Se~i~ 1711 a. <br /> <br />3. Beating equipme~t to comply with the fi.B.C.,Volume II, Mechanical. <br /> <br />4. Any room-e~ntatnin~ a centraul heating p~uaut to be separated from the balance <br />of the building by a 1 hour occupancy seperation, Section ?08. <br /> <br />5. Provide a minimum of t-.;o exits from the lounge ~md from the banquet area. Sec- <br />tion 3302 a and Table 33 A. <br /> <br />6. Exits to be not less than I/5=h of the permeter of the room apart. Distance <br />betwee~ e~ts to be measured in a straight line. Scctio~ 3502 c. Folding doors <br />do not qualify as an e~ntt. Se¢~o~ 3303 f, <br /> <br />7. Exit doors to be openable fro~ the inside without the ~e of a key or special <br />knowledge or effort. Section 3303 C, <br /> <br />size for required doors in 3'0" X 6'8". Section 3303 <br /> <br /> <br />