Permit Address
5983 WALINA CT SE
Permit City
Aumsville
Parcel Number
082W23B 02300
Permit Type
Permit
Permit Site Number
10585
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PorcheS, balconies or raised <br />floor surfaces located more <br />than 30 in, above the floor or <br />grade shall have guardrails not <br />less than 36 in. in <br />Required guardrails shall have <br />intermediate rails or ornamen- <br />tal closures which will not <br />allow passage of an object 6 <br />in , or more in diameter. R- <br />214.2 <br /> <br />installed ogtside of each <br />separate sleeping area in the <br />immed~ ate vicinity of the <br />bedroo~s and on each additional <br />story of the dwelling including <br />basementS, In dwelling units <br />with split levels¢ e smoke <br />detector need be installed only <br />on the upper level, provided <br />the lower level is less than <br />one full story below the upper <br />level, except that if there is <br />a door between levels then a <br />detector is required on each <br />level. All detectors shall be <br />connected to a sounding device <br />or other detectors to provide, <br />when actuated, an alarm which <br />will be audible in all sleeping <br />areas. R-215.1 <br /> <br />28. <br /> <br />22. <br /> <br />In new construction, required <br />smoke detectors shall receive <br />their primary power from the <br />building wiring. Smoke detec- <br />tors may be battery operated <br />when installed in existing <br />buildings. R-215.2 <br /> <br />23. Pirestopping shall be provided <br /> in the following locations: in <br /> concealed spaces of stud walls <br /> at the ceiling, floors,soffits, <br /> drop ceilings, between stair <br /> stringers and at openings <br /> around vents, pipes, ducts, <br /> chimneys and fireplaces at <br /> ceil,ing and floor spaces. R- <br /> 402.7 <br /> <br />24~ Foundation cripple walls shall <br /> be framed of studs with a min. <br /> length of 14 in. or shall be <br /> framed of solid blocking. R- <br /> 402.9 <br /> <br />.;5. The area within the foundation <br /> walls shall have all vegeta- <br /> tion, top soil and foreign <br /> material removed. R-603,2 <br /> <br />Rafters shall be nailed to <br />ceiling joists to for~ a con- <br />tinuous tie between.exterior <br />~all$ where joist are parallel <br />to the rafters. Where not <br />parallel, rafters shall be tied <br />with a rafter tie, located at <br />or near the plate as practical. <br />Rafter ties shall be spaced not <br />more than 4 feet on center. <br /> <br />Ridge board ehall be at least 1 <br />inch nominal thickness and not <br /> <br />less in depth than the cut er]d <br />of the rafter. At all valleys <br />and hips there shall be a <br />valley or hip rafter not less <br />than 2 in. nominal tt%icknesS <br />and not less in depth than the <br />cut end of the rafter, R-702.2 <br /> <br />When the roof pi%ch is less <br />than 3 in 12~ members support- <br />lng rafters and ceiling joist, <br />such as ridge beams, t~ips and <br />valleys, shall be des~g.n<~d a~ <br />beams. R-702.3 <br /> <br />Wood trusses shall bo designed <br />in accordance with approved <br />engiaeering practice. TruSses <br />shall be braced accordi~g to <br />their appropriate eag~neered <br />design. Truss members shall <br />no~ be cut or altered unless <br />so designed. R-702.9 <br /> <br />All plywood, when designed to <br />be exposed in outdoor applica- <br />tions shall be of an exterior <br />type, except that plywood roof <br />sheathing exposed to the <br />underside may be of interior <br />type with exterior glue. R- <br />703.1 <br /> <br />Provide screened attic vents <br />with a net free area of 1/150 <br />of the at~ic area (or 1/300 if <br />half is aloeg eaves and %he <br />other half in uhe upper <br />portion). R-707 <br /> <br /> A readily accessible a~tic <br /> access framed opening not less <br /> than 22 in, by 30 in. shall be <br /> provided. R-708 <br /> <br />33, Fireplace and chimney con- <br /> struction shall conform to <br /> chapter 9. <br /> <br />34, INSULATION i{EQUi REMENTS : <br /> Buildings with high-efficiency <br /> heatiag equipment shall be <br /> insulated as follow: ceiling <br /> R-30 (roof/ceiling assemblies <br /> in which has a slope of 3 in <br /> <br />12 or greater, may be R-19), <br />walls R-il, underfloors R-19, <br />other heating systems, ceiling <br />R-38 (vaulted ceiling <br />walls R-19 and under floor <br />19. <br /> <br />Elements of appliances which <br />create a glow, spark or flame <br />shall be located a min. of 18 <br />in. above garage floor. <br />1114 <br /> <br />Appliances subject to mechani- <br />cal damage shall be guarded by <br />a protective barrier. M-1114 <br /> <br /> <br />