Laserfiche WebLink
CONSTRUCTION <br />(Continued~): <br /> <br />REQUIRE~.EN%'$ <br /> <br />dwelling units having a stairway which <br />opens from the basement into the <br /> <br /> cONSTKgCTION ~KQ~IRZ~EKT$ <br /> (Continued)= , ,~ <br /> <br />/26.7 Vent kitchen fan to <br /> outside <br /> via <br />kq~e~al ducts. <br /> <br />~7~ In bathrooms, water <br /> closet <br />c~mpartments, laundry rooms and <br />similar rooms, a mechanical <br />ventilation system connected <br />directly to the outside, capable of <br />five air changes per hour shall be <br />provided where there are no openable <br />windows. OUBC 1205-a <br /> <br /> 28~r~$~de all habitable rooms <br /> witXh~'outside' ~ windows with net areas <br /> of not less than 1/10 of floor areas <br /> not 10 sq. ft. Every sleeping room <br /> shall have an exterior door or not <br /> less than 5.7 sq. ft. of openable <br /> window. The min. net clear opening <br /> height shall be 24 inches, The min. <br /> net clear opening width shall be 20 <br /> · nches. The finished sill height <br /> shall be not more then 44 inches. <br /> OUBC 1204 and 1205 (a) <br /> <br /> 29. Provide at least one 36" <br /> Swinging (exit) door OUBC 3304 (e) <br /> <br /> 30. Stairs: OUBC 3305 <br /> a. Max. 8" rise. Min, 9" run. <br /> b. Headroom over stairs 6'6" <br /> min. <br /> c. Handrail designed for 20 <br /> lbs. lateral load. Table <br /> 23-c <br /> d. Stairways having less than <br /> 4 risers need not have <br /> handrails. 3306 (j) <br /> <br /> 31. Heating facilities capable of <br /> maintaining a temperature of 68 <br /> degrees F. at a point 3' above the <br /> floor are required in all habitable <br /> roms, OUBC 1211 <br /> <br /> 32. Warm air furnace shall not be <br /> installed in a bedroom or bathroom. <br /> OUMC 704 <br /> <br /> ~ Where bottom of glass light is <br /> ~w~thin 18" of floor and all glass <br /> doors and wall panels of bathtub and <br /> shower enclosures, must be of <br /> laminated, tempered or wire glass. <br /> OUBC 5406 (d) <br /> ~. Approved numbers or addresses <br /> ~s~hall be provided for all new <br /> buildings in such a position as to <br /> be plainly visible and legible from <br /> the street or road fronting the <br /> property. <br />~ Every dwelling shall be <br />k~3~dv%ded with an approved product of <br />combustion detector other than heat <br />mounted on the ceiling or wall at a <br />point centrally located in the <br />corridor or area giving access to <br />sleeping rooms. Where sleeping <br />rooms are on an upper level, the <br />detector shall be placed at the <br />center of t~e ceiling directly above <br />the stairs. Care shall be exercised <br />when locating cold air return to <br />furnace so that air flow to detector <br /> <br />dwelling units having a stairway which <br />opens from the basement into the <br />dwelling. Such detector shall be <br />connected to a sounding device to provide <br />an alarm which will be audible in the <br />sleeping area. OUBC 1210 (a) <br /> <br />36. Loose-fill lnsulatlon. Blown, <br />poured and spray-on type may be used in <br />attic spaces where roof slope is 4 in 12 <br />or grater and there is at least 44" of <br />headroom at the ridge. 5303 (a) 2.A <br /> <br />37. Thermal insulatlon shall not <br />installed within 3" of any metal chimne~ <br />or gas vent. <br /> <br />38. Insulation requirements. <br />Buildings with high-efficiency heat~nc_ <br />equipment such as: <br /> 1. Heat pumps that shows <br /> coefficient of performance as <br /> required ~n Table No. 53-D. <br /> 2. Gas and oil fired that shows s <br /> minimum combustion efficienc~ <br /> of 80 percent Annual Fuel Us~ <br /> Efficiency (AFUE) rating. <br />May have building elements insulated as <br />Fo 1 lows: <br /> Ceiling R-3 0 (roof/ceiling <br /> assemblies in which has a slope of 3 <br /> in 12 or greater, may be R-19). <br /> walls R-19 <br /> Floors R-19 <br />Other Heating systems: <br /> Ceilings R-38 (roof/ceiling <br /> assemblies in which as a slope <br /> of 3 in 12 or greater may be <br /> R-19) <br /> Walls R-19 <br /> Floors R-19 <br /> OUBC 5303 (c)l <br /> <br />39. Slab min. 24" length of R-4.f <br />~nsulation placed between slab and <br />foundation wall, length to includs <br />horizontal and vertical distance. 530~ <br /> (c) 4 <br /> <br /> Weatherstrip doors between heated <br /> unheated areas. <br /> <br />41. Heat ducts installed under floor or <br />in attic shall be provided min. R-4.5 <br /> <br />iNSULATION. <br /> <br />42. R-11 perimeter insulation accepted <br />when crawl space is a plenum. <br /> <br />43~./ Draft baffles are required at eave <br />vents to deflect ventilation air over <br />blown insulation. (OUBC Section) 5303 (a) <br />2A <br /> <br />44. Fireplace and chimney constructios <br />shall conform to chapter 37 OUBC <br /> <br />45. When alterations, repairs, or <br />additions having a valuation of $1,000.0[ <br />occur, or sleeping rooms are added in <br />existing Group R, Division 3 occupancies, <br />the entire building shall be provided <br />with smoke detectors as specified in UBC <br />1210 (a) <br /> <br />46. sky lights set at an angle less than <br />45 degree from horizontal shall be set at <br /> <br /> <br />