Laserfiche WebLink
CONS TR UC T ION R EQUI R EMENTS dwelling units having a stairway which <br /> (Continued): opens from the basement into the <br /> ' ' ' ~ ' ' dwelling. Such detector shall be <br /> ~J. Vent kitchen fan to ou~i~e via connected to a sounding device to provide <br /> ~tal ducts, an alarm which will be audible in the <br /> ~.~ , sleeping area. 0UBC 1210 (a) <br /> . In bathrooms, water closet <br /> compartments, laundry rooms and 36. Loose-fill insulation. Blown, <br /> similar rooms, a mechanical poured and spray-on type may be used in <br /> ventilation system connected attic spaces where roof slope is 4 in 12 <br /> directly to the outside, capable of or grater and there is at least 44" of <br /> five air changes per hour shall be headroom at the ridge. 5303 (a) 2.A <br /> provided where there are no openable <br /> windows. OUBC 1205-a 37. Thermal insulation shall not <br /> ' ' .............. installed within 3" of any metal chimney <br /> 28.~/Provide all habitable rooms or gas vent. <br /> with outside windows with net areas L~--~ <br /> of not less than 1/10 of floor areas 38. Insulation requirements. <br /> not 10 sq. ft. Every sleeping room Buildings with high-efficiency heatin~ <br /> shall have an exterior door or not equipment such as: <br /> less than 5.7 sq. ft. of openable 1. Heat pumps that shows <br /> window. The min. net clear opening coefficient of performance as <br /> height shall be 24 inches. The min. required in Table No. 53-D. <br /> net clear opening width shall be 20 2. Gas and oil fired that shows <br /> inches. The finished sill height minimum combustion efficiency <br /> shall be not more then 44 inches, of 80 percent Annual Fuel Use <br /> OUBC 1204 and 1205 (a) Efficiency (AFUE) rating. <br /> ............ May have building elements insulated a~ <br /> 29. Provide at least one 36" Follows: <br /> Swinging (exit) door OUBC 3304 (e) Ce i 1 ing R-30 (r oof/ceilln9 <br /> ......... assemblies in which has a slope of 3 <br /> 30, Stairs: OUBC 3305 in 12 or greater, may be R-19). <br /> a. Max. 8" rise. Min. 9" run. Walls R-19 <br /> b. Headroom over stairs 6'6" Floors R-19 <br /> min. Other Heating systems: <br /> c. Handrail designed for 20 Ceilings R-38 (roo f/cellin§ <br /> lbs. lateral load. Table assemblies in which as a slope <br /> 23-c of 3 in 12 or greater may be <br /> d. Stairways having less than R-19) <br /> 4 risers need not have Walls <br /> handrails. 3306 (j) Floors R-19 <br /> .............................. OUBC 5303 (c)l <br /> 31. Heating facilities capable of <br /> maintaining a temperature of 68 39. Slab min. 24" length of R-4.5 <br /> degrees F. at a point 3' above the insulation placed between slab and <br /> floor are required in all habitable foundation wall, length to include <br /> roms. OUBC 1211 horizontal and vertical distance. 530~ <br /> ....... (c) 4 <br /> 32. Warm air furnace shall not be ................................. ~ <br /> installed mn a bedroom or bathroom. ~ Weatherstrip doors between <br /> heated <br /> OUHC 704 ~d unheated areas. <br /> <br /> Where bottom of glass light is 41. Heat ducts installed under floor o~ <br /> ~ithln ,18" of floor and all glass in attic shall be provided min. R-4.5 <br /> doors and wall panels of bathtub and ..... , .... <br /> shower enclosures, must be of INSULATION. <br /> laminated, tempered or wire glass. " _i ~2 ~ ..... <br /> OUBC 5406 (d) 42. R-11 perimeter insulation accepted <br /> . when crawl space is a plenum. <br /> 34. Approved numbers or addresses ................ <br /> shall be provided for all new 43. Draft baffles are required at ears <br /> buildings in such a position as to vents to deflect ventilation air ovez <br /> be plainly visible and legible from blown insulation. (OUBC Section) 5303 (a) <br /> the street or road fronting the 2A <br /> property ...... <br /> 44. Fireplace and chimney construction <br /> Ev ry dwelling shall be shall conform to chapter 37 OUBC <br />~ovlded with an approved product of <br />combustion detector other than heat 45. When alterations, repairs, or <br />mounted on the ceiling or wall at a additions having a valuation of $1,000.0C <br />point centrally located in the occur, or sleeping rooms are added in <br />corridor or area giving access to existing Group R, Division 3 occupancies, <br />sleeping rooms. Where sleeping the entire building shall be provided <br />rooms are on an upper level, the with smoke detectors as specified in UBC <br />detector shall be placed at the 1210 (a) <br />center of the ceiling directly above <br />tnt stairs. Care shall be exercised 46. Sky lights set at an angle less than <br />when locating cold air return to 45 degree from horizontal shall be set at <br />furnace so that air flow to detector least 4" above the plane of roof on a <br />from non-sleeping areas is not curb contacted as required for the frame. <br />impeded. A smoke detector shall be <br />installed in the basement of <br /> <br /> <br />