Laserfiche WebLink
CONSTRUCTION REQUIREMENTS dwelling units having a stairway which <br /> (~o~ntinued): opens from the basement into the <br /> ~.. · ...... dwelling. Such detector shall be <br /> Vent kitchen fan to outside via connected to a sounding device to provide <br /> al ducts, an alarm which will be audible in the <br />~ ...... sleeping area. OUBC 1210 (a) <br />~.) In bathrooms, water closet <br />c~Y~partments, laundry rooms and 36. Loose-fill insulation. Blown, <br />slmilar rooms, a mechanical poured and spray-on type may be used in <br />ventilatlon system connected attic spaces where roof slope is 4 in 12 <br />directly to the outside, capable of or grater and there is at least 44" of <br /> flys air changes per hour shall be headroom at the ridge. 5303 (a) 2.A <br />provided where there are no openable <br />windows. OUBC 1205-a 37. Thermal insulation shall not be <br />.................. installed within 3" of any metal chlmne~ <br /> 28. Provide all habitable rooms or gas vent. <br /> with outside windows with net areas <br /> of not less than 1/10 of floor areas /~8~ I~nsulation re'quirements. <br /> not 10 sq. ft. Every sleeping room ~B~dildlngs wzth high-efficiency heatlnc~ <br /> shall have an exterior door or not equipment such as: <br /> less than 5.7 sq. ft. of openable 1. <br /> <br />window. The min. net clear opening <br />~%elght shall be 24 inches. The min/ <br />net clear opening widt~ shall be 20 <br />inches. The finished sill height <br />shall be not more then 44 inches. <br /> <br /> OUBC 1204 and 1205 (a) <br /> <br /> 29. Provide at least one 36" <br /> Swinging (exit) door OUBC 3304 (e) <br /> <br /> 30. Stairs: OUBC 3305 <br /> a. Max. 8" rise. Min. 9" run. <br /> b. Headroom over stairs 6'6" <br /> <br /> c. Handrail designed for 20 <br /> lbs. lateral load. Table <br /> 23-c <br /> d. Stairways having less than <br /> 4 risers need not have <br /> handrails. 3306 (j) <br /> <br /> 31. Heating facilities capable of <br /> maintaining a temperature of 68 <br /> degrees F. at a point 3' above the <br /> floor are required in all habitable <br /> roms. OUBC 1211 <br /> <br /> 32. Warm azr furnace shall not be <br /> installed in a bedroom or bathroom. <br /> OUMC 704 <br />/~3/~ Where bottom of glass light is <br />~-~ithin 18" of floor and all glass <br />doors and wall panels of bathtub and <br />shower enclosures, must be of <br />laminated, tempered or wire glass. <br />OUBC 5406 (d) <br /> <br /> ~ Approved numbers or addresses <br /> ~hall be provided for all new <br /> buildings in such a position as tO <br /> be plaznly visible and legible from <br /> the street or road fronting the <br /> property. <br /> <br /> 35. Every dwelling shall be <br /> provided with an approved product of <br /> combustion detector other than heat <br /> mounted on the ceiling or wall at a <br /> point centrally located in the <br /> corridor or area giving access to <br /> sleeping rooms. Where sleeping <br /> rooms are on an upper level, the <br /> detector shall be placed at the <br /> center of the ceiling directly above <br /> the stairs. Care shall be exercised <br /> when locating cold air return to <br /> furnace so that air flow to detector <br /> from non-sleeping areas is not <br /> impeded. A smoke detector shall be <br /> installed in t~e basement of <br /> <br />Heat pumps that shows ~ <br />coefficient of performance as <br />required zn Table No. 53-D. <br />Gas and oil fired that shows s <br />minimum combustion efficiency <br />of 80 percent Annual Fuel Uss <br />Efficiency (AFUE) rating. <br />bullding elements insulated as <br /> <br /> May have <br /> Fol lows: <br /> Ceiling R-3 0 (roof/ceiling <br /> assemblies in which has a slope of 3 <br /> in 12 or greater, may be R-19). <br /> Walls R-19 <br /> Floors R-19 <br /> Other Heating systems: <br /> Ceilings R-38 (roof/ceilzng <br /> assemblies in whzch as a slope <br /> of 3 in 12 or greater may be <br /> R-19) <br /> Walls R-19 <br /> Floors R-19 <br /> OUBC 5303 (c)l <br /> <br /> 39. Slab min. 24" length of R-4.5 <br /> insulation placed between slab and <br /> foundation wall, length to include <br /> horizontal and vertical distance. 5302 <br /> (c) 4 <br />d doors Oetween neared <br /> Weatherstrlp <br /> unheated areas. <br /> <br /> 41. Heat ducts installed under floor oz <br /> in attic shall be provided min. R-4.5 <br /> <br /> INSULATION. <br /> <br /> 42. R-ii perimeter insulation accepted <br /> when crawl space is a plenum. <br /> <br /> Draft baffles are required at ears <br /> vents to deflect ventilation air over <br /> blown insulation. (OUBC Section) 5303 (a) <br /> 2A <br />~ Fireplace and chimney construction <br />s--hall conform to chapter 37 OUBC <br /> <br /> 45. When alterations, repairs, or <br /> additions having a valuation of $1,000.0C <br /> occur, or sleeping rooms are added in <br /> existing Group R, Division 3 occupancies, <br /> the entire building shall be provide~ <br /> with smoke detectors as specified in UBC <br /> 1210 (a) <br /> <br /><~6/ Sky lights set at an angle less than <br /> 4~5 degree from horizontal shall be set at <br /> least 4" above the plane of roof on a <br /> curb contacted as required for the frame. <br /> <br /> <br />