Laserfiche WebLink
CONSTRUCTION REQUIREMENTS <br />(Continued): <br /> <br />({'621 Vent kltcl~en fan to outside via <br />m&%al ducts, <br /> <br /> 27. In Pathrooms, water Closet <br /> compartmenLs, laundry rooms and <br /> similar rooms, a mechan%cal <br /> yen t ils t Ion system connected <br /> d:rectly to the o~:tslde, capable of <br /> five air changes per hour shall be <br /> provided where there are no openable <br /> windows. OUBC 1205-a <br />"~}-- Provide all ~a~itable rooms <br />. outside windows with net areas <br />of not less than 1/10 of floor areas <br />not 10 sq. ft, Every sleeping room <br />shall have an exterior door or not <br />less than 5.7 sq. ft. of openable <br />w~ndow. The min. net clear opening <br />height shall De 24 Inches. The rain. <br />net clear opening width shall be 20 <br />~nches. Thc finished sill height <br />shall De not more then 44 inches. <br />OUBC 1204 and ~205 (a) <br /> <br />29. Provlde at least one 36 <br />Swinging (exit) door OUBC 3304 (e) <br /> <br /> ---~ a. Max. 8" flsa. Min. 9" r~n. <br /> b, Headroom over stairs 6'6 <br /> <br /> c. Handrail designed for 20 <br /> ids. lateral load. Table <br /> 23-c <br /> d. Stairways having less than <br /> 4 risers need not have <br /> handrails. 3306 <br /> <br />3l. Heatlag £acllities capable of <br />maintaining a temperature of 68 <br />degrees F. at a point 3' above the <br />floes are required in all habitable <br />roms. OUSC 1211 <br /> <br /> 32. Warm air furnace shall not be <br /> ~nstalled in a bedroom or bathroom. <br /> OU~4C 704 <br /> <br /> 33. Whore bottom of glass light is <br /> ~zthln 18" of floor and all glass <br /> doors and wall panels of bathtub and <br /> shower enclosures, must be of <br /> laminated, tempered or wire glass. <br /> O~Jt~C 5406 (d) <br /> <br /> Approved numbers or addresses <br />,~- <br />~[%al i De provided for all new <br /> buildings in such a position as to <br /> be plainly visible and legible from <br /> the street or road fronting the <br /> <br />~3~/~/ Every dwelling shall be <br /> <br />provided with an approved product of <br />combustion detector other than heat <br />mounted on the ceiliag or wall at a <br />poInt centrally located in the <br />corridor or area giving access to <br />sleeping rooms. Where sleeping <br />rooms are on an upper level, the <br />detector shall be placed at the <br />center of t~e ceiling directly above <br />t~lc stairs. Care shall be exercised <br />when locating cold air return to <br />furnace so that air flow to detector <br />from non-sleeping areas is not <br />impeded. A smoke detector shall be <br />installed in the basement of <br /> <br />dwelling units having a s~alrway which <br />opens from the basement z~%to <br />dwelling . Such detector shall se <br />connected to a sounding device to provide <br />an alarm which will be audible In the <br />sleeping area. OUBC 1210 (a) <br /> <br />36. Loose-fill insulation. Blown, <br />poured and spray-on type may be used in <br />attic spaces where roof slope is 4 in 12 <br />or grater and there is at least 44" of <br />headroom at the ridge. 5303 (a) 2.A <br /> <br />37. Thermal insulation shall not be <br />installed within 3" of any metal chimney <br />or gas vent. <br /> <br />38. Insulation requirements. <br />Buildings with high-efficiency heating <br />equipment such as: <br /> 1. Heat pumps that shows a <br /> coefficient of performaece as <br /> required an Table No. 53-D. <br /> 2. Gas and oil fired that stlows a <br /> minlm[n~ combustion e£flclency <br /> of 80 percent Annual Fuel Use <br /> Effzclency (AFUE) rating. <br />May have building elements lnselated as <br />Follows: <br /> Ce£11ng R-30 (roof /cell~ ng <br /> assemblies in which has a slope of <br /> in 12 or greater, may be <br /> Walls R-19 <br /> Floors R-19 <br />other Heating systems: <br /> Ceilings R-38 (roof/ceiling <br /> assemblies Ln which as a slope <br /> of 3 in 12 or greater may be <br /> R-19) <br /> Walls R-19 <br /> Floors R-19 <br /> OUBC 5303 <br /> <br />39. Slab min. 24" length of <br />insulation placed between slab and <br />foundation wall, length to include <br />horizontal and vertical distance. 5303 <br />(c) 4 <br /> <br />40. Weatherstrip doors bet. ween heated <br />and unheated areas. <br /> <br />41. Heat ducts installed under floor <br />in attic shall be provided min. R-4.5 <br /> <br />INSULATION. <br /> <br />accepted <br /> <br />42. R-11 perlmcter insulation <br />when crawl space is a plenum. <br /> <br />43. Draft baffles are required at ease <br />vents to deflect ventilation air over <br />blown insulation. (OUBC Section) 5303 (a) <br />2A <br /> <br />44. Fireplace and chimney construction <br />shall conform to chapter 37 OUBC <br /> <br />45. When alterations , repairs, or <br />additions having a valuation of <br />occur, or sleeping rooms are added <br />existing Group R, Division 3 occupancies, <br />the entire building shall be provided <br />with smoke detectors as specified in gBC <br />1210 (a) <br /> <br />46. Sky lights set at an angle less than <br />45 degree from horizontal shall be set at <br />least 4" above the plane of roof on <br />curb contacted as required for the frame. <br /> <br /> <br />