My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1268926
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
Old Files 5
>
Permit - 1268926
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2011 10:31:34 AM
Creation date
9/2/2003 3:51:56 PM
Metadata
Fields
Template:
Permits
Permit Address
9263 PORTER RD SE
Permit City
Aumsville
Permit Type
Permit
Permit Site Number
6646
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CONSTRUCTION REQUIREMENTS (continued):. <br /> <br /> ,tinued) than 5.7 sq. ft. of opqna~ <br /> 24" <br /> no dimension less than an~ Sll| <br />height not over 44". S. 1304 and 5, <br />1404 and 5 <br /> <br />~2. Windows between the carport and the dwel- <br />.]...i.n§ shall not be openable. S. 1412. <br />33. Provide at least one 36" swinging (exit)-- <br />door. S. 3303-d <br /> <br />34. Stairs: <br /> Maximum 8" rise, Minimum 9" run. <br /> b. Headroom over stairs 5'6" minimum. <br /> c. Handrail required for stairways of <br /> 4 or more risers on open sides 30" <br /> above grade/one side. OUBC 3303. <br /> d. Handrail designed for 20 lbs. lateral <br /> load. Table 23-c <br />35. Heating facilities capable of maintaining <br />a temperature of 70 degrees F. at a point 3' <br />above the floor are required in~l habitable <br />rooms. S. 1410 <br /> <br /> 36. Warm air furnace shall not be installed <br /> under any stairway nor in a bedroom or bath- <br /> j~qm. UMC S. 704 <br />~f~.~ Where bottom of glass light is~ithin 18" <br /> of floor and all glass doors and wall panels <br /> of bathtub and shower enclosures, must be of <br /> laminated, tempered or wire glass. OUBC 5406 <br /> A~l~s~o~ see Federal Glazing Standard. <br /> ~a Every dwelling shall be provided with <br /> pproved product of combustion detector <br /> other than heat mounted on the ceiling or <br /> wall at a point centrally located in the <br /> corridor or area giving access to sl6eping <br /> rooms. Where sleeping rooms are on an up- <br /> per level, the detector shall be placed at <br /> the center of the ceiling directly above the <br /> stairs. All detectors shall be placed within <br /> 12~' of ceiling. Care shall be exercised when <br /> locating cold air return to furnace so <br /> that air flow to detector from non-sleeping <br /> ~C~ 9~t impeded. OUBC 1413 <br /> eiling, R-30 minimum. <br /> Exterior walls, R-11 min. w/foil back. <br /> Underfloor, R-19. <br /> Groundcover min. OC~visqu~e~ min. <br /> 40_ Slab min~ ~ length of R-4.5 insul~tf66 <br /> placed between slab and foundation wall, <br /> length to include horizontal and vertical <br /> z~ta~e~ ..... <br /> F~. Neatherstrip doors between heated and <br /> ~f~eated areas. <br />~ Heat ducts installed under floor or in <br /> attic shall be provided min, R-4.5 insulation. <br /> <br /> 43. R-4.5 perimeter insulation accepted when <br />C~dJ....q.p.ace is heated~ <br /> Draft baffles are required at eave vents <br /> eflect ventilating air over blown insula- <br /> <br /> OUBC Section 5309) <br /> Fireplace and chimney construction shall <br />nform to Chapter 37 UBC. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.