Laserfiche WebLink
~C N $~% RUCTION REQUIREMENTS <br />/Continued): <br /> <br />~6~,J Vent kitchen fan to outside via <br />~etal ducts. <br /> <br />{Tp In bathrooms, water closet <br />.'%mpartments , laundry rooms and <br />~lml lar rooms, a mechanical <br />,entilation system connected <br />~irectly to the outside, capable of <br />lye air changes per hour shall be <br />>rovlded where there are no openable <br />~lndows. OUBC 1205-a <br />~-~ Provide all habitable rooms <br />~lth outside windows with net areas <br />~f not less than 1/10 of floor areas <br />~ot 10 sq. ft. Every sleeping room <br />,hall ~ave an exterior door or not <br />cbs ti%an 5.7 sq. ft. of openable <br />,,io. dow. Fha min. net clear opening <br />,eight shall be 24 inches. Tae min. <br />~et c~ear opening width shall be 20 <br />.nones. 'I~h_e_ ~inls_he_d .sill height <br />~h~ll. Ou ao~ more then ~4- inch'es. <br />3USC 1204 and 1205 '(a) <br /> <br />!9, Provide at least one 36" <br />~w]nglng (exit) door OUBC 3304 <br /> <br />Stairs: OUBC 3305 <br />a. Max. <br />b. Headroom over stairs 6'6" <br /> mln. <br />c. Handrail. designed for 20 <br /> lbs, lateral load. Table <br /> 23-c <br />d. Stairways having less than <br /> 4 risers need not have <br /> handrails. 3306 (j) <br /> <br />31. Heating facilities capable of <br />r~aintazning a temperature of 68 <br />~egrees P. a% a point 3' above the <br />floor are required in all habitable <br />toms, OUBC 1211 <br /> <br />32. Warm air furnace shall not be <br />~nstalled in a bedroom or bathroom. <br />~UMC 704 <br /> <br />~3~2 Where bottom of glass light is <br />~lthin 18" of floor and all glass <br />Joors and wall panels of bathtub and <br />shower enclosures, must be of <br />laminated, tempered or wire glass. <br />)UBC 5406 d) <br /> <br /> 34. Approved numbers or addresses <br /> ~hall be provided for all new <br /> 3uildlngs in suc~ a position as <br /> }e plainly visible and legible from <br /> 5he street or road fronting the <br /> 3roperty. <br /> <br />~2 Every dwelling shall be <br />X~ovlded with an approved product of <br />~ombust~on detector other than heat <br />~ounted on the ceiling or wall at a <br />0oint centrally located in the <br />corridor or area giving access to <br />sleeping rooms. Where sleeping <br />uooms are on an upper level, the <br />detector shall be placed at the <br />center of the ceiling directly above <br />the stairs. Care shall be exercised <br />~hen locating cold air return 'to <br />.f~rnace so that air flow to detector <br />from non-sleeping areas zs not <br />~mpeded. A smoke detector shall be <br />~ns~alled in the basement of <br /> <br />dwelling units having a stairway wh].cll <br />opens from the basemcnt into the <br />dwelling , Such detector shall be <br />connected to a sounding device to provldc <br />an alarm which will be audible In the <br />sleeping area. OUBC 1210 (a) <br /> <br /> 36. Loose-fill insulation. Blown, <br /> poured and spray-on type may be used in <br /> attic spaces where roof slope is 4 in 12 <br /> or grater and there is at least 44" of <br /> headroom at the ridge. 5303 (a) 2.A <br /> <br />/37. Thermal insulation shall not be <br /> installed within 3" of any metal chimney <br /> or gas vent. <br /> <br />38. Insulation requirements. <br />Buildings with high-efficiency ~eatlnq <br />equipment such as: <br /> 1. Heat pumps that shows a <br /> coefficient of performa~%ce as <br /> required in Table No. 53-D. <br /> 2. Gas and oil flred that shows a <br /> minimum combustion efficiency <br /> of 80 percent Annual Fuel [/se <br /> Efficiency (AFUE) rating. <br />May have building elements insulated as <br />Follows: <br /> Ceil 1 ng R- 3 0 ( roof/cei 1 lng <br /> assemblies in which has a slope of 3 <br /> in 12 or greater, may Os R-19). <br /> Walls R-19 <br /> Floors R-19 <br />Other Heating systems: <br /> Ceilings R-35 (roof/ceiling <br /> assemblies in which as a slope <br /> of 3 in 12 or greater may be <br /> R-19) <br /> Walls R-19 <br /> Floors R-19 <br /> OUBC 5303 (c)l <br /> <br />39. SlaO min. 24" length of R-4.5 <br />Insulation placed between slab and <br />foundation wall, length to include <br />horizontal and vertical distance. 5303 <br /> ............. <br />40. Weatherstrip doors between <br />and unheated areas. <br /> <br />heated <br /> <br />41. Heat ducts installed under floor or <br />in attic shall be provided min. R-4.5 <br /> <br />INSULATION. <br /> <br />42. R-ii perimeter insulation accepted <br />when crawl space is a plenum. <br /> <br />43. Draft baffles are required at eave <br />vents to deflect ventilation air over <br />blown insulation. (OUBC Section) 5303 {a) <br />2A <br /> <br />44. Fireplace and chimney construction <br />shall conform to chapter 37 OUBC <br /> <br />45. When alterations, repairs, or <br />additions having a valuation of $1,000.00 <br />occur~ or sleeping rooms are added in <br />existing Group R, Division 3 occupancies, <br />the entire building shall be provided <br />with smoke detectors as speclfled in UBC <br />1210 (a) <br /> <br />46. Sky lights set at an angle less than <br />45 degree from horizontal shall be set at <br />least 4" above the plane of roof on a <br />curb contacted as required for the frame. <br /> <br /> <br />