Laserfiche WebLink
CONSTRUCTION REQUIREMENTS <br /> (Continued): , , ~ ~ <br /> <br /> Vent kitchen fan to outside via <br />~r~etal ducts. <br /> <br /> 27. In bathrooms, water closet <br /> compartments, laundry rooms and <br /> similar rooms, a mechanical <br /> ventilation system connected <br /> d~rectly to the outside, capable of <br /> f~ve air changes per hour shall be <br /> provided where there are no openable <br /> windows, OUBC 1205-a <br /> <br />28. Provide all habitable rooms <br />wltt~ outside windows with net areas <br />of not less than 1/10 of floor areas <br />not 10 sq. ft. Every sleeping room <br />shall have an exterior door or not <br />less than 5.7 sq. ft. of openable <br />window. The m~n. net clear opening <br />hc~ght shall De 24 inches. The m~n. <br />net ctear opening width s~lall De 20 <br />znct~es ~ The finished sill height <br />s~%all be not more then 44 inches. <br /> <br />OUBC 1204 and 1205 <br /> <br />29. Provide at least <br />Swinging (ex~t) door OUBC <br /> <br />30. Stairs: OUBC 3305 <br /> a. <br /> <br />o n,e 3 6" <br />3304 (e) <br /> <br />Max. 8" rise. Mln. 9" run. <br />Headroom over stairs 6' 6" <br /> <br />Handrail designed for 20 <br />lbs. lateral load. Table <br />23-c <br />Stairways having less than <br />4 risers need not have <br />handrails, 3306 <br /> <br />31. Heating facilities capable of <br />maintaining a temperature of 68 <br />degrees F. at a point 3' above the <br />floor are required in all habitable <br />roms. OUBC 1211 <br /> <br />32. Warm a~r furnace shall not be <br />~nstalled ~n a bedroom or bathroom. <br />OUMC 704 <br /> <br />33. Where bottom of glass light is <br />within 15" of floor and all glass <br />doors and wall panels of bathtub and <br />shower enclosures, m~st be of <br />laminated, tempered or wire glass. <br />OUBC 5406 (d) <br />Approved numbers addresses <br /> 11 be provided for all new <br />buildings in such a position as to <br />be plaj. r~ly visible and legible from <br />the street or road fronting the <br />property. <br />~ Every dwelling shall be <br />p'i-ovlded with an approved product of <br />combustion detector other than heat <br />mou~lted on the ceiling or wall at a <br />point centrally located in the <br />corridor or area giving access to <br />sleeping rooms. Where sleeping <br />rooms are on an upper level, the <br />detector shall be placed at the <br />center of the ceiling directly above <br />the stairs. Care shall be exercised <br />when locating cold air return to <br />furnace so that air flow to detector <br />from non-sleeping areas is not <br />impeded, A smoke detector shall be <br />installed in the basement of <br /> <br />dwelling unlts having a stairway whlcln <br />opens from the basement ~ nto the <br />dwelllng. Such detector shall be <br />connected to a sounding device to provide <br />an alarm which will be audible in the <br />sleeping area. OUBC 1210 (a) <br /> <br />36. Loose-fill insulation. Blown, <br />poured and spray-on type may be used ~n <br />attic spaces where roof slope is 4 in 12 <br />or grater and there is at least 44" of <br />headroom at the ridge, 5303 {a) 2.A <br /> <br />37. Thermal insulation shall not be <br />installed within 3" of any metal chlmney <br />or gas vent. <br /> <br />38. Insulation requirements. <br />Buildings <br />equipment <br /> 1, <br /> <br /> with high-efficiency heating <br /> such as: <br /> Heat pumps that shows a <br /> coefficient of performance as <br /> required in Table NO. 53-D. <br />Gas and oil fired that allows a <br />minimum combustion efficiency <br />of 80 percent Annual Fuel Use <br />Efficiency (AFUE) far.rig. <br />May have building elements insulated as <br />Follows: <br /> Ceil lng R- 3 0 (roof/ceiling <br /> assemblies in which has a slope of 3 <br /> in 12 or greater, may be R-19). <br /> Walls R~19 <br /> Floors R-19 <br />Other Heating systems: <br /> Ceilings R-38 (roof/ceiling <br /> assemblies in which as a slope <br /> of 3 in 12 or greater may be <br /> R-19) <br /> Walls R-19 <br /> Floors R-19 <br /> OUBC 5303 (c)l <br /> <br />39. Slab mln . 24" length of R-4 , 5 <br />insulation placed between slab and <br />foundation wall, length to include <br />horizontal and vertical distance. 5303 <br />(c) 4 <br /> <br />40. Weatherstr~p doors between heated <br />and unheated areas. <br /> <br />41. Heat ducts installed under floor or <br />in attic shall be provided min. R-4.5 <br /> <br />INSULATION. <br /> <br />42. R-11 perimeter insulation accepted <br />when crawl space is a plenum. <br /> <br />43. Draft baffles are requmred at eave <br />vents to deflect ventilation air over <br />blown insulation. (OUBC Section) 5303 (a) <br />2A <br /> <br />44. Fireplace and chimney construction <br />shall conform to chapter 37 OUBC <br /> <br />45. When alterations, repairs, or <br />additions having a valuation of $1,000.00 <br />Occur, or sleeping rooms are added ~n <br />existing Group R, Division 3 occupancies, <br />the entire building shall be provided <br />with smoke detectors as specified ~n UDC <br />1210 (a) <br /> <br />46. Sky l~ghts set at an angle less than <br />45 degree from horizontal shall be set at <br />least 4" above the plane of roof on a <br />curb contacted as required for the frame. <br /> <br /> <br />