Continued): <br /> <br /> ~ Vent kitchen fan to outside via <br /> ~tal ducts. <br /> <br />7. In bathrooms, water closet <br />ompartments, laundry rooms and <br />imllar rooms, a mechanical <br />entilatlon system connected <br />irectly to the outside, capable of <br />ive air changes per hour shall be <br />rovided where there are no openab!e <br />lndows. OUBC 1205-a <br />· ~th Provide all habitable rooms <br /> outside windows with net areas <br />f not less than 1/10 of floor areas <br />ot 10 sq. ft. Every sleeping room <br />hall have an exterior door or not <br />ess than 5.7 sq. ft. of openab!e <br />indow. The min. net clear opening <br />eight shall be 24 inches. The min. <br />et clear opening width shall be 20 <br />nches. The finished sill height <br />hall be not more then 44 inches. <br />,UBC 1204 and 1205 (a) <br /> <br />9. Provide at least one 36" <br />winging (exit) door OUBC 3304 (e) <br /> <br /> Stairs: OUBC 3305 <br /> a. Max. 8" rise. Min. 9" run. <br /> b. Headroom over stairs 6'6" <br /> <br /> c. Handrail designed for 20 <br /> lbs. lateral load.' Table <br /> 23-c <br /> d. Stairways having less than <br /> 4 risers need not have <br /> handrails. 3306 (j) <br /> <br />:1. Heating facilities capable of <br />laintaining a temperature of 68 <br />[egrees F. at a point 3' above the <br />loot are required in all habitable <br />· oms. OUBC 1211 <br /> <br /> 2. Warm air furnace shall not be <br />nstalled in a bedroom or bathroom. <br />~UMC 704 <br /> <br />3. Where bottom of glass light is <br />,ithin 18" of floor and all glass <br />loots and wall panels of bathtub and <br />.bower enclosures, must be of <br />aminated, tempered or wire glass. <br />~UBC 5406 (d) <br />~. Approved numbers or addresses <br />~all be provided for all new <br />luildings in such a position as to <br />~e plainly visible and legible from <br />~ne street or road fronting the <br />,roper ty. <br /> <br />'~. Every dwelling shall be <br />~rovlded with an approved product of <br />:ombust~on detector other than heat <br />~ounted on the ceiling or wall at a <br />~oint centrally located in the <br />:orridor or area giving access to <br />~leeping rooms. Where sleeping <br />'ooms are on an upper level, the <br />ietector shall be placed at the <br />:enter of the ceillng directly above <br />:he stairs. Care shall be exercised <br />~hen locating cold air return to <br />!urnace so that air flow to detector <br />rom non-sleeping areas is not <br />mpeded. A smoke detector shall be <br />nstalled in the basement of <br /> <br />opens from the basement into the <br />dwelling. Such detector shall be <br />connected to a sounding device to provide <br />an alarm which will be audible 'in the <br />sleeping area. OUBC 1210 (a) <br /> <br />36. Loose-fill insulation. Blown, <br />poured and spray-on type may be used in <br />attic spaces where roof slope is 4 in 12 <br />or grater and there is at least 44" of <br />headroom at the ridge. 5303 (a) 2.A <br /> <br />37. Thermal insulation shall not be <br />installed within 3" of any metal chimney <br />or gas vent. <br /> <br />38. Insulation requirements. <br />Buildings with high-efficiency heating <br />equipment such as: <br /> 1. Heat pumps that shows a <br /> coefficient of performance as <br /> required in Table No. 53-D. <br /> 2. Gas and oil fired that shows a <br /> minimum combustion efficiency <br /> of 80 percent Annual Fuel Use <br /> Efficiency (AFUE) rating. <br />May have building elements insulated as <br />Follows: <br /> Ceiling R-3 0 (roof/ceiling <br /> assemblies in which has a slope of 3 <br /> in 12 or greater, may be R-19). <br /> Walls R-19 <br /> Floors R-19 <br />Other Heating systems: <br /> Ceilings R~38 (roof/ceiling <br /> assemblies in which as a slope <br /> of 3 in 12 or greater may be <br /> R-19) <br /> Walls R-19 <br /> Floors R-19 <br /> OUBC 5303 (C)i <br /> <br />39. Slab min. 24" length of R-4.5 <br />insulation placed between slab and <br />foundation wall, length to include <br />horizontal and vertical distance. 5303 <br /> (c) 4 <br /> <br />40. Weatherstrip doors between heated <br />and unheated areas. <br /> <br />41. Heat ducts installed under floor or <br />in attic shall be provided min. R-4.5 <br /> <br /> INSULATION. <br />~, ...... '~" ,. .:_:::~ ~ [ ~ . <br /> 42. R-11 perimeter insulation accepted <br /> when crawl space is a plenum. <br /> <br /> 43. Draft baffles are required at eave <br /> vents to deflect ventilation air over <br /> blown insulation. (OUBC Section) 5303 (a) <br /> 2A <br /> <br /> 44. Fireplace and chimney construction <br /> shall conform to chapter 37 OUBC <br /> <br /> 45. When alterations, repairs, or <br /> additions having a valuation of $1,000.00 <br /> occur, or sleeping rooms are added in <br /> existing Group R, Division 3 occupancies, <br /> the entire building shall be provided <br /> with smoke detectors as specified in ~BC <br /> 1210 (a) <br /> <br /> 46. Sky lights set at an angle less than <br /> 45 degree from horizontal shall be set at <br /> least 4" above the plane of roof on a <br /> curb contacted as required for the frame. <br /> <br /> <br />