Laserfiche WebLink
STAT~ OF OREGON <br /> DEPARTMENT OF COMNERCE <br /> Aumsville Elementary <br />Building School, Shop Addn <br /> <br />- PLANS REVIEW SECTION <br /> <br /> na~ <br />County Marion Occupancy E-1/B-2 <br /> <br />Arch./Engr. Craig Carlson <br /> <br />NOTICE OF PLAN REVIEWS/ <br /> (THIS IS NOT A BUILDING PERHIT} <br /> <br /> 572Nllth~Aumsville' No. 403-86 <br /> <br /> Const. 5-1hr Sound Value $14,000 Plan Fee $41.80 <br />New Bldg.__Addition X~Alteration__ bate Received 06/18/86 <br /> <br />Owner same Address same Date Reviewed 06/26/86 <br /> none -- 1 2 / 9 ~ <br />Stories 1 Area 835 / N/S Attic .v.= / Fire Walls -2hrExits t, <br /> Stops <br />Stairs no~/e no Vert,Sbafts non~ -~prtnklers ~ / -- Man.Alarm N/S S.P. nop/e --/ -- <br /> closed ~lbsed no yes area covered iht, size ~ <br />Ext~ N/~/ ~-Ht. Oet. S / part Floor cone Ceiling gYP Roof bltup Str. Members wood <br /> 'class no. ty'pe' area covo. <br />Wall Cover wood / gyp Htr.~bltEncl. N/S Type Flue N/S Type Htg,System N/S Fuel N/S <br /> ext, iht. <br /> <br />The submitted plans have been reviewed for conformity with fire protection statutes and regulations of Oeegon adminis- <br />tered by this office, The following provisions must be incorporated into the project to meet current fire protection <br />regulations. Approval of submitted plans is not an approval of omissions or oversights by this office or of noncom- <br />pliance with any' appl'icable ~egula~ion$ of I~cal government, <br /> <br />REMARKS: <br /> <br /> 1) This is a Fire & Life Safety Plan Review covering the construction of the <br />above addition to the existing building. This review is for compliance w~th the fire & life <br />safety provisions of the Oregon State Structural Specialty Code and fire and life safety <br />regulations 83 edition. <br /> <br />2) This plans review covers a 835 sq. ft. addition to an existing building. <br /> <br />3) When buildings are required to be one-hour fire resistive construction, soffet vents and <br />gable vents are not permitted: Ref. PPPI, Page 4118 and Ref. Code, Sec. 4304(0). <br /> <br />4) Exit doors shall be openable from the inside without the use of a key or any special <br />knowledge or effort. Manually operated edge or surface bolts are prohibited: Ref. Code, <br />Sec. 3304(c). <br /> <br />5) Portable fire extinguishers shall be provided and installed as required by applicable <br />standards and as directed by the authority having Jurisdiction. <br /> <br />6) The roof covering material is required to be fire retardant: Ref. Code, Sec. 3202B. <br /> <br />7) The protection of the ceiling shall be of an approved one-hour fire-resiative assembly: <br />Ref. Code, Sec. 2201 and Table 43-C. <br /> <br />8) The plans for the above-indicated addition are acceptable as submitted subject to the <br />items noted above and the approval of the authority having jurisdiction. <br /> <br />MARION COUNTY <br />BUILDING INSPECTION <br /> <br /> Dene Ray <br /> <br />_ Examined By: <br /> <br /> Dept., <br /> Elec,, Arch,/Engr, <br /> Plbg, <br /> <br /> <br />