Laserfiche WebLink
Onsite Permit 555-24-006706-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555026119324 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Dat $sued SI2Tf2 �, .� 4. ratlonbdat 8/2" <br /> ,F- � a'4�ew h • � �.� � �* x :gym q,k � « a" <br /> urk desanptl<an N a e TA!L CSR FOTU '"4Hi SI=E} <br /> Special Requirements <br /> Groundwater type: Temporary Groundwater depth: N/A <br /> Groundwater interceptor: Yes Groundwater interceptor depth: 48 in. <br /> Groundwater interceptor drain media amt: 36 in. <br /> Other special rqmt: Replacement Area Changed to An"System <br /> Conditions of approval: <br /> •Dry soil installation only(June 1—October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> -Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum diameter if less <br /> than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the construction plan approved <br /> by the agent,including any changes made by the agent. <br /> •AII work is to conform to OAR 340,Division 71 and 73.Make no changes in system location or specifications without approval by the <br /> agent. <br /> -For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •An anti-buoyancy device is required for the septic tank(s)and must be installed as per the manufacturer installation guidelines. <br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must be placed on top of the effluent sewer or <br /> pressure transport pipe from tank to drainfield. <br /> •Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before connecting to the distribution unit.It <br /> must be installed with a minimum fall of 4 inches per 100 feet and at least 2 inches of fall from one end of the pipe to the other.In <br /> addition,there must be a minimum difference of 8 inches between the invert of the septic tank outlet and either the invert of the header <br /> to the distribution pipe of the highest lateral in a serial distribution field or the invert of the header pipe to the distribution pipes of an equal <br /> distribution absorption field. <br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length,level,and bedded. <br /> -Each drainfleld trench must be level within a tolerance of plus or minus 1-inch. <br /> •Maximum length of an individual trench is 150-feet. <br /> -Serial distribution,each trench bottom to be level and on contour.Use Drop box(es). <br /> Groundwater Interceptor,Curtain Drain required:Minimum trench width 12-inches.Minimum perf pipe diameter 4-inches;must meet <br /> the requirements in OAR 340-073-0060(4);and must be installed at least 2 inches above the bottom and along the full length of the <br /> trench with a minimum of 10 inches of drain media cover The curtain drain must be filled with drain media to within 12 inches of the <br /> ground surface with filter fabric placed over the media.The outlet pipe(s)must be rigid smooth-wall,solid PVC pipe meeting or <br /> exceeding ASTM Standard D-3034 with a minimum diameter of 4 inches.A flap gate or rodent guard must be installed.The curtain drain <br /> must extend at least 6 inches into the layer that limits effective soil depth or to a depth adequate to effectively dewater the site. <br /> 8/27/24:1:42:12PM ONS OnsitePermit pr <br />