Laserfiche WebLink
Onsite Permit 555-23-006799-PRMT Page 3 of 4 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555062798173 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> 4.Date Issued 8f24123 � ,E m ptratton date 8t23124 <br /> 414 W ri 3 �`,?�e� °� °" a s 41rt sYKt rA <br /> VrKriip'siftptioivo,hw INSTAL F©l,4 BD* fr y y" j3 qte4 a <br /> 311i �� �.,i�F. .��'Jsr�,.�-a��'.��. ww"�y. �a.y�. _. -�. ....,'. l <br /> Conditions of approval <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business <br /> (installer). <br /> -Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •AII tanks must be tested for watertightness and have a water-tight riser to the ground surface. <br /> Twenty- inch minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than <br /> 36-in deep. Maintain access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance <br /> with the construction plan approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or <br /> specifications without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> -An anti-buoyancy device is required for the septic tank(s) and must be installed as per the <br /> manufacturer installation guidelines. <br /> •A minimum 18-gauge, green jacketed tracer wire or green color-coded metallic tape must be <br /> placed on top of the effluent sewer or pressure transport pipe from tank to drainfield. <br /> Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before <br /> connecting to the distribution unit. It must be installed with a minimum fall of 4 inches per 100 feet and <br /> at least 2 inches of fall from one end of the pipe to the other. In addition, there must be a minimum <br /> difference of 8 inches between the invert of the septic tank outlet and either the invert of the header to <br /> the distribution pipe of the highest lateral in a serial distribution field or the invert of the header pipe to <br /> the distribution pipes of an equal distribution absorption field. <br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length, level, and bedded. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> •Maximum length of an individual trench is 150-feet. <br /> •Serial distribution, each trench bottom to be level and on contour. Use Drop box(es). <br /> -Groundwater Interceptor,Curtain Drain required: Minimum trench width 12-inches. <br /> Minimum perf pipe diameter 4-inches; must meet the requirements in OAR 340-073-0060(4); <br /> and must be installed at least 2 inches above the bottom and along the full length of the <br /> trench with a minimum of 10 inches of drain media cover The curtain drain must be filled with <br /> drain media to within 12 inches of the ground surface with filter fabric placed over the media. <br /> The outlet pipe(s) must be rigid smooth-wall,solid PVC pipe meeting or exceeding ASTM <br /> Standard D-3034 with a minimum diameter of 4 inches.A flap gate or rodent guard must be <br /> installed.The curtain drain must extend at least 6 inches into the layer that limits effective <br /> soil depth or to a depth adequate to effectively dewater the site. <br /> 8/24/23:8:03:27AM ONS_OnsitePermitpr <br />