1 <br /> 1 <br /> NOTES <br /> ., 129 1/8" ,. 1. Airline piping to FAST+ may not exceed 70 FT[21 m]total length <br /> [328]' 59 1/"4.' and have a maximum of 5 elbows in the piping system(@ 70FT <br /> -.4 - 21 m]).For distances greater than 70FT[21 m]consult factory. <br /> [150.5] Blower must be located above flood levels on a concrete base <br /> 26"X 20"X 2"[65 X 50 X 5cm)min. <br /> 2. Vent to be located above finish grade or higher to avoid <br /> infiltration.Cap with a vent grate with at least 7.1 sq in.[45.8 sq. <br /> cm]open surface area.Secure with stainless steel screws. <br /> or <br /> Run Vent to desired location and cover opening with a vent <br /> grate with at least 7.1 sq in.(45.8 sq.cm]open surface area. <br /> Secure with stainless steel screws.Vent piping must not allow <br /> r condensate build up or create back pressure.Vent must be <br /> ' , 1 29 3/4" above finished grade or higher. <br /> � "' 'j I All appurtenances to FAST®(e.g.tanks,access ports, electrical, <br /> i , <br /> etc.)must conform to all applicable country,state,province, <br /> - T and local plumbing and electrical codes. 1 <br /> 4. All inspection,viewing and pump out ports must be secured to <br /> prevent accidental or unauthorized access. <br /> 5. Tank,piping,conduit,etc.are provided by others.Blower ( <br /> control system by Bio-Microbics,Inc.See Installation Manual <br /> 6. All piping and ancillary equipment installed after FAST®must ) <br /> 31810 MIN Vent not impede nor restrict free flow of effluent. 1 <br /> All and <br /> plumbing <br /> See note 2 venting must use 7. The air supply line into the FAST®unit must be secured to <br /> Inspection/Pump water tight gaskets 4, rr10 0� prevent vibration induced damage.The air supply line should <br /> out arts see note 4&7 FAST a secured with a non-corrosive clamp every 2'min[60 cm]. <br /> P <br /> Tank Inlet from <br /> settling zone (., See note 3,4,&5 effluent pipe 8. Min:height may be reduced,consult factory and reference a <br /> see note 6&7 "Short-FAST-Module-Procedure.pdf'. s <br /> rvi Airline to blower 4. Refer to Bio-Microbics supplement '%M-IOBOSupplement'for <br /> see note 1 °. 7,/4" installation details. <br /> see Hate 8 10. Nitrogen reduction beyond standard levels may require specific <br /> featuresfactoryfor 10 beguidance.incorporated into the tank design.Consult <br /> ; rr <br /> APPROVED <br /> F� x y Oregon DEQ on June 12, 2012 <br /> 43 3/8" <br /> ' 0] <br /> E2 al DO NOT SCALE <br /> STATE CERTIFIE® :, <br /> J NLESS NOTED o 1VIIMBICS <br /> f environmental Health Specialist �DIMENSIONS,T REIN INCHES <br /> tv EH-S-10��•5q w <br /> Treatment Volume eENTIMETERS] i 14 a a R P O R s z E D <br /> 1060 Gallons(4000 L) 8 3/8" 12" — 6 5/8",. � � 1 0O p2 IN/IN <br /> I <br /> [21] [30] [17], \• <br /> I ,#'_, l IM1060Installation ` <br /> fv' �� (t 0.05 cm/cm]y Pcb`rt Goodwin WEIGHT lb SIZE DRAWING NUMBER <br /> a a tL it ..NAME DATE SHEET <br /> THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO,MICROBiCS INC.ANY REPRODUGTiON IN PART OR�iS�AR� A FAST 0.5 Layout <br /> WI IDLE WITHOUT THE WRITTEN PERMISSION OF ElO MICROBiCS INC.IS PROHIBITED.DESIGN AND INVENUON RIGHTS ARE RESERVEQ.IN THE B]O-MICR0B]CS©2012 DRAWN crc 3/7/2012 I OF 2 <br /> INTEREST OF TECHNOLOGICAL ADVANCEMENT;ALI.PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE. CHECKED PF 4n7l2012 REVISEDAtt7(201z I REV. INI-01-� <br />