Laserfiche WebLink
Onsite Permit 555-24-001686-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule"to 1-888-299-2821 use IVR Number:555055654457 <br /> Schedule using the Oregon ePermitting Inspection App,search"epermitting"in the app store <br /> ed 3 4I24 t„, ,. <br /> ,� � q �` � � � .- � ��� r ication tlate�4l2S <br /> � V <br /> escrt no N 4 BC3RM 5FD *.11 <br /> e ^ ,. .a A w. .Y1, <br /> Trench length: 450 linear ft. Rock above pipe: N/A <br /> Max depth: 26 in. Undisturbed soil between trenches: 8 ft. <br /> Min depth: 24 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Groundwater type: Temporary Groundwater depth: 26 in. <br /> Other special rqmt: No road cuts larger than 2ft or they must maintain a 50ft setback <br /> Conditions of approval <br /> 'Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> 'The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> 'Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> 'Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent,including any changes made by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73.Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.govideq/Residential/Pages/Onsite.aspx <br /> 'An anti-buoyancy device is required for the septic tank(s)and must be installed as per the <br /> manufacturer installation guidelines. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> 'Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before connecting to the <br /> distribution unit. It must be installed with a minimum fall of 4 inches per 100 feet and at least 2 inches of fall from <br /> one end of the pipe to the other. In addition,there must be a minimum difference of 8 inches between the invert of <br /> the septic tank outlet and either the invert of the header to the distribution pipe of the highest lateral in a serial <br /> distribution field or the invert of the header pipe to the distribution pipes of an equal distribution absorption field. <br /> -Header pipe from Distribution or Drop Box must be minimum 4-ft length, level,and bedded. <br /> 'Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> 'Maximum length of an individual trench is 150-feet. <br /> 'Serial distribution,each trench bottom to be level and on contour. Use Drop box(es). <br /> 3/4/24:1:29:38PM ONS OnsitePermitj,r <br />