Laserfiche WebLink
•:: Marion County <br /> Nam, 5155 Silverton Rd NE <br /> Septic Authorization Approval Salem,OR 97305 <br /> Marton <br /> County 503-588-5147 <br /> 555-23-001897-AUTH Building@co.marion.or.us <br /> o.:R E c;'o:ri Website:co.marion.or.us <br /> Residential Authorization <br /> ta€ie sn �9 4 Dgeri ptr[ g 8/291 £ <br /> � n , <br /> k rS S IRE t U'H. 1 asp `a"'iy 3 4 S f 3+m "§ •� �S ^(1"i/,5, 3 <br /> W©r)(G 1'38SGrrpttn , 4 � �� ,� � /� `� <br /> � � +r�+w7a7 P�+ !; ,_•a g. ,,..,. ..E .«*2vm,',,.:-? ,^w«,"� "`0.w' 'Sa' i3&, ns3; "i ~ �u�., <br /> Applicant: Owen Construction, Inc. Primary Contractor: Owen Construction, Inc. <br /> Address: P.O.Box 21150 Installer License: 38534 <br /> Keizer OR 97307 Address: P.O.Box 21150 <br /> Phone: 503-339-5776 Keizer OR 97307 <br /> Email: williams@owenconstructioninc.com Phone: (503)390-6936 <br /> Email: keith@owenconstructioninc.com <br /> Owner: BOYANTON, HUGH E Property Address: 125 Santiam Ave W, Detroit,OR 97342 <br /> Address: 288 HOLDER LN SE <br /> SALEM OR 97306 <br /> Parcel: 105E02DA03000-Primary <br /> Accessory Dwelling Unit: No <br /> Authorization Notice for: Replacing One Dwelling with Another <br /> Lot Size: N/A Water Supply: Community Water Supply <br /> Category of Construction: Single Family Dwelling <br /> Number of Bedrooms: 2 2 <br /> Conditions of approval: <br /> This notice establishes that the onsite wastewater treatment system located on the property identified above appears adequate by <br /> field inspection/record review to serve a 2-Bedroom single family dwelling with a peak sewage flow of 300 gallons per day. <br /> The system was approved on 8/29/2024 and is a 1500 gallon septic tank and pump with a seepage bed. Maintain all required <br /> setbacks.Vehicular traffic and livestock must be restricted from the system area.All roof drains must be directed away from the <br /> system. <br /> Note:This Notice does not guarantee satisfactory or continuous operation of the sewage system.Should the system fail,a repair <br /> permit from DEQ is required. <br /> If you disagree with this report,you have the right to apply for an authorization notice denial review.The application for review must <br /> be submitted in writing within 45 days of the report issuance and be accompanied by the review fee in OAR 340-071-0140(3),Table <br /> 9C and any additional information DEQ needs to complete the review. <br /> You may apply for a variance to the onsite wastewater treatment system rules. The variance application must include a copy of <br /> the site evaluation report,plans and specifications for the proposed system,specify the rule(s)to which a variance is being <br /> requested,demonstrate the variance is warranted,and include the variance fee in OAR 340-071-140 Table 9C. A variance may <br /> only be granted if the variance officer determines that strict compliance with a rule is inappropriate or special physical conditions <br /> render strict compliance unreasonable,burdensome or impractical. A senior DEQ variance officer will be assigned the variance <br /> application. <br /> Matt Knudsen Onsite Wastewater Specialist 8/29/24 <br /> CALL BEFORE YOU DIG...mS THE LAW <br /> ATTENTION:Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth by Oregon Administration Rules. You may obtain <br /> copies of the rules by calling the center.(Note:The telephone number for the Oregon Utility Notification Center is 1-800-332-2344.) <br /> 8/29/24:3:07:12PM Page 1 of 1 ONS_OnsiteAuthorization_pr <br />