r 't, "' • - " t , ' 1---"' `3' -� 1® m se ' ' t `� �Orenco *e otaQ1,P - . ;r.
<br /> PF Series 60-H -
<br /> z 4 inch 10OñTii4 'BUILDING INECTION
<br /> uNrst
<br /> Submersible Effluent
<br /> Pumps
<br /> Applications Features/Specifications
<br /> Our 4-inch(100-mm)Submersible Effluent Pumps are designed to To specify this pump for your installation,require the following:
<br /> transport screened effluent(with low TSS counts)from septic tanks or • Minimum 24-hour run-dry capability with no deterioration in pump life
<br /> separate dosing tanks.All our pumps are constructed of lightweight, or performance*
<br /> corrosion-resistant stainless steel and engineered plastics;all are field- • Patented 1/8-inch(3-mm)bypass orifice to ensure flow recirculation
<br /> serviceable and repairable with common tools; 60-Hz PF Series models for motor cooling and to prevent air bind
<br /> are CSA certified to the U.S.and Canadian safety standards for effluent
<br /> pumps,meeting UL requirements. • Liquid end repair kits available for better long-term cost of ownership
<br /> Orenco's Effluent Pumps are used in a variety of applications,includ- • TRI-SEALTm floating impeller design on 10,15,20,and 30 gpm
<br /> (0.6,1.0,1.3,and 1.9 L/sec)models;floating stack design on 50 and
<br /> ing pressurized drainfields,packed bed filters,mounds,aerobic units, 75 gpm(3.2 and 4.7 L/sec)models
<br /> effluent irrigation,effluent sewers,wetlands,lagoons,and more.These • Franklin Electric Super Stainless motor,rated for continuous use and
<br /> pumps are designed to be used with a Biotube®pump vault or after a frequent cycling
<br /> secondary treatment system. • Type SCOW 600-V motor cable
<br /> _---- — Discharge Connection 'Not applicable for 5-hp(3.73 kW)models
<br /> Standard Models
<br /> See specifications chart,pages 2-3,for a list of standard pumps.For
<br /> ,—,,, a complete list of available pumps,call Orenco.
<br /> .(1 — Bypass Orifice Product Code Diagram
<br /> '' PF 0
<br /> )
<br /> Franklin I., —
<br /> Liquid End • ;: `t j -
<br /> Cord length,ft(m):$
<br /> t' Blank= 10(3) 20 = 20(6)
<br /> ts ( 30 =30(9) 50 = 50(15)
<br /> Check valve:
<br /> Blank=no internal check valve
<br /> 11
<br /> — Suction Connection CV =Internal check velvet
<br /> Voltage,nameplate:
<br /> 1 =115* 200= 200
<br /> 9-'•;---. 2=230 4 = 460
<br /> 4
<br /> % `� 3-TO Frequency:
<br /> 1 =single-phase 60 Hz
<br /> 3=three-phase 60 Hz
<br /> Franklin S Jr i. Horsepower(kW):
<br /> ,- ) 03=lit hp(0.25) 05=34 hp(0.37)
<br /> Super Stainless ,.,'t, c 07=�a hp(0.56) 10= 1 hp(0.75) 1
<br /> Motor '1 �° ` 't 15=134 hp(1.11) 20=2 hp(1.50)
<br /> z, •`i - 30=3 hp(2.24) 50=5 hp(3.73)
<br /> , Nominal flow,gpm(L/sec):
<br /> 10= 10(0.6) 15= 15(1.0)
<br /> l, -' :'..` `t 20=20(1.3) 30=30(1.9)
<br /> 50 =50(3.2) 75= 75(4.7)
<br /> Pump,PF Series
<br /> Powered by 'Si-hp le for 10 only
<br /> ,Th Available for 10 gpm(0.6 Usec),1/2 hp(0.37 kw)only
<br /> a
<br /> Franklin Electric 'Note.20-ftcardsare available only for single-phase pumps through114hp
<br /> CUS
<br /> LR80980
<br /> LR2053896
<br /> Orenco Systems®Inc.,814 Airway Ave.,Sutherlin,OR 97479 USA•800-348-9843.541-459-4449•www.orenco.com NTD-PU-PF-1
<br /> Rev.4.0,012t16
<br /> Page 1 of 5