Laserfiche WebLink
Onsite Permit 555-23-007123-PRMT Page 3 of 4 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule"to 1-888-299-2821 use IVR Number:555056530596 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> suedI25 x Ex favy S <br /> Workvdescrtption MAJ�)REP.�TO REPI DRAIN .• � ; 0, , 4 ' 5 <br /> �..._•F. . , .,,�., :�'`7��,� - ;--_.. 't v'�-= ,....<,.a,..,. -'.r ..t"`,.x�'�^. • ....�S. air 4. . .._ �,. <br /> Conditions of approval <br /> •This permit is for the installation of an Alternative Treatment Technology(ATT)system and <br /> is to be installed by a person certified by the system manufacturer in accordance with OAR <br /> 340-071-0600 and 0650.See Alternative Treatment Technology rules at OAR 340-071-0345. <br /> •ATT treatment standard 1 required. <br /> •The ATT system must be designed to prevent untreated waste from passing into the <br /> absorption field if the treatment system malfunctions. <br /> •The septic tank must be approved for use with the ATT system to be installed. <br /> •In addition to the As-Built and Materials List, a Start-Up checklist from the ATT <br /> maintenance provider is required to Final this permit. <br /> •The owner of an ATT system must maintain a contract with a maintenance provider <br /> certified by the manufacturer to inspect,adjust and maintain the onsite system.The <br /> maintenance provider must submit an annual report and annual evaluation fee. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> -Vehicular traffic and livestock must be restricted from the system area. <br /> •AII roof drains must be directed away from the system <br /> -All tanks must be tested for watertightness and have a water-tight riser to the ground <br /> surface.Twenty-inch minimum diameter if less than 36-in deep.Thirty-inch minimum <br /> diameter if greater than 36-in deep. Maintain access to septic tank for pumping and service. <br /> -Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in <br /> accordance with the construction plan approved by the agent, including any changes made <br /> by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system loca on <br /> or specifications without approval by the agent. <br /> -For product approval information and manufacturer installation requirements see I Q <br /> website at: http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •The pump and alarm must be wired on separate circuits in the control panel. P p wiring <br /> must comply with applicable building, electrical,or other codes.An electrical p: mit and <br /> inspection from the Department of Consumer and Business Services, Buildin Codes <br /> Division, or the municipality with jurisdiction, is required for pump wiring in allation. <br /> -Install the pump and system components in accordance with the appro -d pump curve and <br /> specifications. <br /> •A minimum 18-gauge, green jacketed tracer wire or green color-coded metallic tape must <br /> be placed on top of the effluent sewer or pressure transport pipe from tank to drainfield. <br /> -Effluent filter required at tank outlet. <br /> -Header pipe from Distribution or Drop Box must be minimum 4-ft length, level, and <br /> 1betidgal. r.'a t°,,. •' ,s; +., i; • <br /> actfdrainfield trench must be level`within`atoleraneejof plus,or minus 1-in ch'Serial,distribution,r :I-1 <br /> each trench bottom to be level and on contour. Use Drop box(es). <br /> 12/5/23:10:11:42AM ONS_OnsitePermitpr <br />