My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12293650
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
23-XXXXXX
>
12293650
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2024 1:21:36 PM
Creation date
7/30/2024 2:34:46 PM
Metadata
Fields
Template:
Permits
Permit Address
2664 BODHI LN NE
Permit City
Salem
Permit Number
555-23-009984-PRMT
Parcel Number
072W13CB00701
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Septic Permit 555-23-009984-PRMT Page 2 of 3 <br /> -`tea ,�..._, ��" , ,_,�,..�.,'" F+x +� 'va � � ,tr"� "F a S •°��.. ,� g. t��'"` "aw ���' <br /> Matt of f�Ga a(6SU@d Q /26 02 a�, �� r + a`� t <br /> VW-0 a +tlo ' s E, -105213 =,),; s : r , <br /> PW <br /> • i �!,, -s:«�.� e.` 'It'.R+ « ... .�, w a`` � � a.a-,� '����• «-tom 5' i,.. <br /> fl9 ■yZ j x° eF! {Mfg <br /> X91/9}t1QR9l1P}LO £, e`xG .kA : <br /> •Capping fill rules at OAR 340-071-0265.Construction must occur in dry soil conditions between June 1 and October 1 unless <br /> otherwise approved by the agent.The cap material must be pre-approved by the agent prior to placement.Minimum 10-ft between <br /> edge of fill and trench. Drainfield area must be scarified.Contact between native soil and fill must be mixed.Final cap to be seeded <br /> and or landscaped to prevent erosion.Protect from livestock and vehicular traffic. <br /> •Serial distribution.The capmaterial must be evenlygraded to a final dep <br /> th of 16-inches over the drain media. <br /> P <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum diameter if <br /> less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain access to septic tank for pumping and <br /> service. <br /> •Meet all required setbacks <br /> •All work is to conform to OAR 340,Division 71 and 73.Make no changes in system location or specifications without approval <br /> by the agent. <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with applicable building, <br /> electrical,or other codes.An electrical permit and inspection from the Department of Consumer and Business Services, Building <br /> Codes Division,or the municipality with jurisdiction,is required for pump wiring installation. <br /> •Serial distribution,each trench bottom to be level and on contour.Use Drop box(es). <br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must be placed on top of the effluent sewer <br /> or pressure transport pipe from tank to drainfield. <br /> -An anti-buoyancy device is required for the septic tank(s) and must be installed as per the manufacturer <br /> installation guidelines. <br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in <br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above. <br /> 1.In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of <br /> satisfactory completion of an onsite wastewater treatment system at the location identified above. <br /> 2.Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will <br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system. <br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect <br /> the soil or the functioning of the system.Such activities may include,but are not limited to,vehicular traffic, livestock, <br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities. <br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance <br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or <br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply,including payment <br /> of an additional fee. <br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard <br /> or pollute public waters. <br /> 6.Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the <br /> issuance of this Certificate of Satisfactory Completion. <br /> q kifi atee t tati04009 149,1: 0.0 9..0 �`- <br /> System Inspection: Yes Operation of Law-7 Days Notice: No Pre-Cover Inspection Waived Per 340-071: No <br /> Comments: A Certificate of Satisfactory completion was issued on 07/26/2024 and the system is authorized to connect to a New <br /> 4BDRM Single Family Dwelling. <br /> Inspector Inspection Inspection Date Inspection Result <br /> Danielle Brown 7999 Final Septic 07/26/2024 Approved <br /> Danielle Brown 7100 Septic Tank 03/12/2024 Approved <br /> 7/26/24:3:11:56PM ONS_OnsiteCSC_pr <br />
The URL can be used to link to this page
Your browser does not support the video tag.