Laserfiche WebLink
Onsite Permit 555-23-005626-PRMT Page 3 of 4 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555067881055 <br /> Schedule using the Oregon ePermitting Inspection App,search"epermitting"in the app store <br /> Date issued:11/21/23`; Expiration date 131/20/24 <br /> Work,description -MAJ REP.-CHRUCH 250=SEATS :.: <br /> Conditions of approval <br /> •This permit is for the installation of an Alternative Treatment Technology(ATT)system and is to be installed by <br /> a person certified by the system manufacturer in accordance with OAR 340-071-0600 and 0650.See Alternative <br /> Treatment Technology rules at OAR 340 071 0345 <br /> An electrical permit*and,mspectton from th_e Department of Consumer and Bust ess Services, <br /> _3 111diri CUdekEki'tmgatjanth'e=mmtiriidi alit�with`•t5ri`sdictiOnris-re cared-for umy wtriti •'installation. <br /> �u 9 p Y �J q' p p- 9- <br /> •ATT treatment standard 1 required. <br /> •The ATT system must be designed to prevent untreated waste from passing into the absorption field if the <br /> treatment system malfunctions. <br /> •The septic tank must be approved for use with the ATT system to be installed. <br /> •In addition to the As-Built and Materials List, a Start-Up checklist from the ATT maintenance provider is <br /> required to Final this permit. <br /> •The owner of an ATT system:must maintain.a contract.with:a maintenance,provider.certified by the <br /> manufacturerto.inspect adjust,and maintain the onsite.system:-Theamaintenance,provid'ef must submit_an'annual <br /> report and annual`eValuatiorrfee, r <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep.Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340,Division 71 and 73. Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building,electrical,or other codes. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Effluent filter required at tank outlet,commercial system. <br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length,level,and bedded. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> •The hydrosplitter must be located at least 6 inches higher than the piping in the highest disposal trench to <br /> ensure that effluent in the top line does not spill back into the hydrosplitter. <br /> •The system using a hydrosplitter is to be pressurized only to the hydrosplitter,and is to utilize gravity flow from <br /> the hydrosplitter to the disposal trenches. <br /> •The hydrosplitter must be enclosed in a secure enclosure with a solid,watertight bottom to eliminate the effect <br /> of rodents filling the enclosure with soil. <br /> 11/21/23:10:07:58AM ONS_OnsitePermitpr <br />