My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12293635
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
23-XXXXXX
>
12293635
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2024 2:25:34 PM
Creation date
7/30/2024 2:33:45 PM
Metadata
Fields
Template:
Permits
Permit Address
155 SANTIAM AVE W
Permit City
Detroit
Permit Number
555-23-006940-PRMT
Parcel Number
105E02DA02700
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• <br /> Schedule B:SERVICES <br /> OWNS RESPONSIBILITIES <br /> 1.- Visually inspect the system and disposal field MONTHLY <br /> A&B SEPTIC SERVICE RESPONSIBILITIES <br /> 1.. System Maintenance and Servicing perforrned SEMI ANNUALLY <br /> A. Maintain Processing Tank <br /> 1. Measure sludge and-scum <br /> 2. Check tank for pumping <br /> B. Maintain Pump Tank: <br /> 1, inspect/clean pump as needed <br /> 2. Inspect/clen biotube as needed <br /> 3. Activate all floats <br /> 4. Check/record:clarity(turbidity). <br /> .5 Check.for odor(sniff) <br /> - _- __. -_.6: Check for oily film visual inside tank <br /> 7. Check,for foam(visual inside tank) <br /> 8. Check/record pH <br /> 9. Measure sludge and scum: <br /> .9 Record motor arnps. <br /> 11. Record ETM'sand event counters <br /> 12 Verify all timer settings <br /> 13. Check splice.box <br /> C. Maintain disposal field <br /> 1 Visually inspect disposal field surface for ponding <br /> 2. Check liquid level in disposal field's monitoring ports if installed in system, <br /> 3. Flush laterals if designed according to DEQ <br /> D. Reporting <br /> 1 Report to authorized representative any=impropersystem function and date <br /> of correction. <br /> 2. Annual report to Regulatory Agency with Regulatory Agency Fee. <br /> Homeowner will be invoiced for Regulatory Agency Fee annually,and <br /> the fee is to be paid directly to A&B Septic within 10 days of invoicing. <br /> If the fee is not paid within the specified time frame,the report will <br /> not be sent to the Regulatory Agency,and the homeowner will be out <br /> of compliance.. <br /> E. Alarm/Emergency Response. <br /> 1 Service Tech on call 24 hours a day,7 days a week: <br /> 2_ Provide Emergency Response within 48 hours of service request <br />
The URL can be used to link to this page
Your browser does not support the video tag.