Laserfiche WebLink
Oregon Department of Environmental Quality <br /> • The septic tank material is: <br /> E Concrete <br /> Steel <br /> E Plastic <br /> Fiberglass <br /> El Other(explain) <br /> r Unknown <br /> • Is the septic tank accessible? ®Yes nNo <br /> • Septic tank volume in gallons 3000 <br /> • Tank volume determined by: Check all that apply, add comments below as needed <br /> ®Permit Records 0 Measured❑ Stamped on Tank❑ Other <br /> • Septic tank risers are at ground level ®Yes [No <br /> • Tank appears to be free from defects,leaking and signs of deterioration®Yes ❑No <br /> If you answered"No,"please describe the condition of the septic tank below.For example, <br /> evidence of gas corrosion,cracks,leaks, etc. <br /> • Septic tank lid(s)is intact ®Yes ❑No <br /> • Septic tank baffles are intact: Inlet Yes [-No Outlet EYes ❑No <br /> • Baffle material-Inlet PPlastic ❑Concrete DMetal Outlet pPlastic EConcrete ❑Metal <br /> Effluent filter is present Yes ❑No <br /> • Effluent filter is free of debris ®Yes ONO ❑Not Applicable <br /> • Liquid level in tank relative to invert of outlet At ❑Above ❑Below <br /> If above or below invert outlet,please explain: <br /> • Scum layer 8 (inches) Sludge layer 12 (inches) <br /> • Scum and Sludge layer more than 35%of the total tank volume ❑Yes [✓]No <br /> Indicate where sludge measured from: ❑✓Inlet ['Middle ❑Outlet <br /> • Additional Comments: <br /> 4. Dosing tank/Pump Basin <br /> Dosing tanks use a pump to send effluent to a treatment unit or a soil absorption field. <br /> • The septic system has a dosing tank ®Yes fNo <br /> (If"No,"skip the rest of section 4) <br /> • At the time of this evaluation the power was on to test the pump(s): ®Yes ❑No <br /> Page 3 of 8 <br />