My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12271038
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
23-XXXXXX
>
12271038
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2024 11:37:58 AM
Creation date
7/18/2024 1:21:16 PM
Metadata
Fields
Template:
Permits
Permit Address
306 MONITOR RD
Permit City
Silverton
Permit Number
555-23-006413-PRMT
Parcel Number
061W26DD01800
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• <br /> Oregon llepaitment of Environmental Quality <br /> • Dosing tank capacity (gallons) <br /> • Tank volume determined by:Check all that apply,add comments below as needed <br /> 0 Permit Records 0 Measured 0 Stamped on Tank 0 Other <br /> • Dosing tank material <br /> • Dosing tank appears to be watertight and in good condition DYes ONo <br /> • Dosing tank lid is intact DYes DNo <br /> • Electrical components are sealed and watertight :Wes ONo <br /> • Pump/siphon is functional DYes DNo <br /> • Type of Pump 0Demand dose. 0Time dose <br /> • Pump control mechanism is functional(floats,pressure transducer)DYes DNo <br /> • There is a higb water alarm 0Yes DNo <br /> • The high water alarm(audible and visual)is working :Wes DNo 0Not Applicable <br /> • Type of screen <br /> • Screen is clean and free of debris DYes ONo-Screen cleaned for this evaluation Dies ONo. <br /> • Scum/sludge present in Dosing tank DYes DNo <br /> • Scum layer (inches) Sludge layer (inches) <br /> • Additional Comments: <br /> 5. Soil absorption system <br /> The soil absorption system is a set of trenches that receives effluent from the septic tank and <br /> filters the effluent before it enters the groundwater. <br /> • The septic system has a soil absorption system gRes ONo ['Unknown <br /> • Was the soil absorption system part of the evaluation?0Yes 0No ['See note below <br /> If the soil absorption system was not evaluated,please explain below(for example unable to <br /> locate,client did not authorize this part of the evaluation): <br /> • Absorption distribution 0Equal 0Serial OPressure °Equal via pressure <br /> • Absorption lines construction material: <br /> 0 Gravel and pipe 0 Chamber 0 Tile 0 Polystyrene foam and pipe 00ther Corrigaled pipe <br /> • Absorption distribution unit(s):Ddropbox Dhydrosplitter[Thqual distribution box <br /> LZI Intact El Damaged 0 N/A <br /> • Absorption distribution unit(s)are free of debris or solids 01/es 0No El N/A <br /> Page 4 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.