My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12267774
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
23-XXXXXX
>
12267774
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2024 2:17:34 PM
Creation date
7/16/2024 4:50:54 PM
Metadata
Fields
Template:
Permits
Permit Address
330 JANICE CT
Permit City
Detroit
Permit Number
555-23-008352-PRMT
Parcel Number
105E02DA06400
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Septic Permit 555-23-008352-PRMT Page 2 of 3 <br /> 64tpiv4�i 6144it jirlit71 ittkii � <br /> Vifor�le�cnptarE� ,i~lEUU INSTALL 3 BDR>RFD„„ N `Ag <br /> b .b d 0i +&,r;- v k.,. g " ,i irk y` "'' ' <br /> �,' , a ¢� 147 <br /> n ,s � sr CndltlonSfi� EOYarp i � <br /> e ,. .. Y-,.R kc ba.. �....., M�a.,:..e �K ;3..., _/�a. - -: � >m:..m,a#,i.,e -., ,. .5 ., .„�_�r,..z k ._.a at �. <br /> •ATT treatment standard 1 required. <br /> •This permit is for the installation of an Alternative Treatment Technology(ATT)system and is to be <br /> installed by a person certified by the system manufacturer in accordance with OAR 340-071-0600 and 0650. <br /> See Alternative Treatment Technology rules at OAR 340-071-0345. <br /> •The septic tank must be approved for use with the ATT system to be installed. <br /> •In addition to the As-Built and Materials List, a Start-Up checklist from the ATT maintenance provider is <br /> required to Final this permit. <br /> •The owner of an ATT system must maintain a contract with a maintenance provider certified by the <br /> manufacturer to inspect,adjust and maintain the onsite system.The maintenance provider must submit an <br /> annual report and annual evaluation fee. <br /> •Gravelless absorption method rules at OAR 340-071-0290 (6). Pressurized distribution required w/ <br /> distribution piping perforated with 1/8 inch diameter orifices on maximum 2-foot centers at the 12 o'clock <br /> position and at least a 2-foot residual head at the distal orifice. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business (installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty- <br /> inch minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. <br /> Maintain access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •AII work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or <br /> specifications without approval by the agent. <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply <br /> with applicable building, electrical, or other codes.An electrical permit and inspection from the Department <br /> of Consumer and Business Services, Building Codes Division,or the municipality with jurisdiction, is <br /> required for pump wiring installation. <br /> •A minimum 18-gauge, green jacketed tracer wire or green color-coded metallic tape must be placed on <br /> top of the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Pressurized distribution rules at OAR 340-071-0275. Install sweep elbows at ends of lateral piping with <br /> acceptable threaded plugs or caps. Minimum head of 5-ft at remotest orifice, less than 10%variation. <br /> •The owner of a pressurized distribution system must maintain a contract with a certified maintenance <br /> provider to inspect, adjust and maintain the onsite system.The maintenance provider must submit an <br /> annual report and annual evaluation fee. <br /> • <br /> 7/11/24:8:27:28AM ONS_OnsiteCSCjr <br />
The URL can be used to link to this page
Your browser does not support the video tag.