Laserfiche WebLink
Onsite Permit 555-23-004352-PRMT-01 Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555051237080 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Date issued:8/3/23 • V ± Expiration date:8/2/24 <br /> Work'description MAJ REP REPLACE FAILING DRAINFIELD <br /> Media type description: EZ Flow <br /> Trench length: 375 linear ft. Rock above pipe: N/A <br /> Max depth: 36 in. Undisturbed soil between trenches: 8 ft. <br /> Min depth: 24 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Other special rqmt: 10'setback to driveway, possible historical property line <br /> If installation is to take place on West side of driveway,an easement may be required. <br /> Conditions of approval <br /> 'The existing tank must be placed on a tank water tightness test. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> 'Vehicular traffic and livestock must be restricted from the system area. <br /> •All roof drains must be directed away from the system <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> -All work is to conform to OAR 340, Division 71 and 73.Make no changes in system location or specifications <br /> without approval by the agent. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> -Effluent sewer.The effluent sewer must extend at least 5 feet beyond the septic tank before connecting to the <br /> distribution unit. It must be installed with a minimum fall of 4 inches per 100 feet and at least 2 inches of fall from <br /> one end of the pipe to the other. In addition,there must be a minimum difference of 8 inches between the invert of <br /> the septic tank outlet and either the invert of the header to the distribution pipe of the highest lateral in a serial <br /> distribution field or the invert of the header pipe to the distribution pipes of an equal distribution absorption field. <br /> 'Header pipe from Distribution or Drop Box must be minimum 4-ft length, level,and bedded. <br /> -Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> 'Maximum length of an individual trench is 150-feet. <br /> 'Serial distribution,each trench bottom to be level and on contour. Use Drop box(es). <br /> • <br /> 8/3/23:11:47:31AM ONS_OnsitePermitpr <br />