Pump Selection for a Non-Pressurized System-Single Family Residence Project <br /> Parameters <br /> Discharge Assembly Size 1.50 inches 100 <br /> Transport Length 70 feet <br /> Transport Pipe Class 40 <br /> Transport Line Size 1.25 inches 90 <br /> Distributing Valve Model None <br /> Max Elevation Lift 5 feet <br /> Design Row Rate 30 gpm <br /> 80 <br /> Flow Meter None inches <br /> 'Add-on'Friction Losses 0 feet <br /> Calculations 70 <br /> Transport Velocity 6.5 fps y <br /> m <br /> Frictional Head Losses s 60 <br /> 0 <br /> Loss through Discharge 2.7 feet ~ . <br /> Loss in Transport 7.8 feet m <br /> Loss through Valve 0.0 feet X 50 <br /> Loss through Rowmeter 0.0 feet <br /> 'Add-on'Friction Losses 0.0 feet m <br /> Pipe Volumes To' 40 <br /> Vol of Transport Line 5.4 gals 1 PFEF40-13 I <br /> Minimum Pump Requirements 30 <br /> Design Flow Rate 30.0 gpm <br /> Total Dynamic Head 15.5 feet <br /> 20 <br /> 10 <br /> 00 20 40 60 80 100 120 140 160 <br /> Net Discharge(gpm) <br /> PumpData Legend <br /> PFEF40 Effluent Pump System Curve:- <br /> 4/10HP,115/230V 10 <br /> Pump Curve:— <br /> Pump Optimal Range:— <br /> Operating Point: <br /> : -^ Design PoinY.0 <br /> 17:-C...; <br /> Environmental Health Specialist <br /> EH- 1022757 <br /> OrrenC0 mry <br /> SYSTEMS <br /> DEBNESSOMMEMMi <br />