Laserfiche WebLink
Septic Permit 555-23-007417-PRMT Page 2 of 3 <br /> Naetetfcaaess reidi2 24 44(4 1',n 3 ,t� <br /> aldRE � " l. `y r y* �Work escri lion. f 4 Ft'' <br /> , +� t, = Ct7 n ittoriS o Approvd <br /> •This permit is for the installation of an Alternative Treatment Technology(AU)system and is to be installed by a person certified <br /> by the system manufacturer in accordance with OAR 340-071-0600 and 0650.See Alternative Treatment Technology rules at OAR <br /> 340-071-0345. <br /> •ATT treatment standard 1 required. <br /> •The AU system must be designed to prevent untreated waste from passing into the absorption field if the treatment system <br /> malfunctions. <br /> •The septic tank must be approved for use with the AU system to be installed. <br /> •In addition to the As-Built and Materials List,a Start-Up checklist from the ATT maintenance provider is required to Final this <br /> permit. <br /> •The owner of an ATT system must maintain a contract with a maintenance provider certified by the manufacturer to <br /> inspect,adjust and maintain the onsite system.The maintenance provider must submit an annual report and annual <br /> evaluation fee. <br /> •Gravelless absorption method rules at OAR 340-071-0290(6).Pressurized distribution required w/distribution piping perforated <br /> with 1/8 inch diameter orifices on maximum 2-foot centers at the 12 o'clock position and at least a 2-foot residual head at the distal <br /> orifice. <br /> •Dry soil installation only(June 1—October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> •AII roof drains must be directed away from the system <br /> -All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum diameter if <br /> less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain access to septic tank for pumping and <br /> service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the construction plan <br /> approved by the agent,including any changes made by the agent. <br /> -All work is to conform to OAR 340,Division 71 and 73. Make no changes in system location or specifications without approval <br /> by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> •The pump and alarm must be wired on separate circuits in the control panel.Pump wiring must comply with <br /> applicable building,electrical,or other codes.An electrical permit and inspection from the Department of Consumer <br /> and Business Services,Building Codes Division,or the municipality with jurisdiction,is required for pump wiring <br /> installation. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must be placed on top of the effluent sewer <br /> or pressure transport pipe from tank to drainfield. <br /> •Maximum length of an individual trench is 150-feet. <br /> .Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> 7/1/24:9:51:25AM ONS_OnsiteCSCJr <br />