Laserfiche WebLink
Marion County <br /> 5155 Silverton Rd NE <br /> Marton Septic Authorization Approval Salem,OR 97305 <br /> ,County 503-588-5147 <br /> 555-24-004427-AUTH Building@co.marion°or°us <br /> O,REG37 N,. <br /> Residential Authorization Website:co.marion.or.us <br /> !k a&r a �* t'` . g-•<:' .� ' s �, « a " d gg� a <br /> 3a 1ssud: 124 r, Dat Expiring�74'/25 x •' '^ <br /> o ff A T ADD BDRM TQ EXiS ;N 3B®RM'SF0 TO "4BDRM <br /> ltkfot�c� a ocx �� <br /> '$7.1 4 as Y a ,,. #.� . i " eel, t� <br /> Applicant: SHETLER, PETER E&SHETLER, Primary Contractor: SEE PROPERTY OWNER <br /> JENNY L INFORMATION <br /> Address: 1448 CASCADE HY SE Owner(Property): OWNER <br /> SALEM OR 97317 <br /> Phone: 503-507-7459 <br /> Email: PETERSHELTER@GMAIL.COM <br /> Owner: SHETLER,PETER E&SHETLER, Property Address: 1448 Cascade Hwy SE,Salem,OR <br /> JENNY L 97317 <br /> Address: 1448 CASCADE HY SE <br /> SALEM OR 97317 <br /> Parcel:071W34 01700-Primary <br /> Accessory Dwelling Unit: No <br /> Authorization Notice for: Addition of One or More Bedrooms <br /> Lot Size: 5 acres Water Supply: Well <br /> Category of Construction: Single Family Dwelling <br /> Use of Structure: 3 bedroom home 4 bedroom home <br /> Number of Bedrooms: 3 4 <br /> System Specifications: <br /> Max Peak Design Flow: 450 gpd Proposed Gallons per Day: 225 gpd <br /> Other Special Requirement: The current septic system was installed 1/13/78 and consists of 450 total drainfield and a 1000 <br /> gallon concrete tank.A site visit was made on 6/18/24 and it appears that the septic system is <br /> functioning.Under OAR 340-071-0205 with an increase in flow that does not exceed an increase of <br /> 300 gpd this increase in flow is approved for connection. <br /> Conditions of Approval: <br /> Note:This Notice does not guarantee satisfactory or continuous operation of the sewage system.Should the system fail,a repair <br /> permit from DEQ is required. <br /> If you disagree with this report,you have the right to apply for an authorization notice denial review.The application for review must <br /> be submitted in writing within 45 days of the report issuance and be accompanied by the review fee in OAR 340-071-0140(3),Table <br /> 9C and any additional information DEQ needs to complete the review. <br /> You may apply for a variance to the onsite wastewater treatment system rules. The variance application must include a copy of <br /> the site evaluation report, plans and specifications for the proposed system,specify the rule(s)to which a variance is being <br /> requested,demonstrate the variance is warranted,and include the variance fee in OAR 340-071-140 Table 9C. A variance may <br /> only be granted if the variance officer determines that strict compliance with a rule is inappropriate or special physical conditions <br /> render strict compliance unreasonable,burdensome or impractical. A senior DEQ variance officer will be assigned the variance <br /> application. <br /> CALL BEFORE YOU DIG..°ITS THE LAW <br /> ATTENTION:Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth by Oregon Administration Rules. You may obtain <br /> copies of the rules by calling the center.(Note:The telephone number for the Oregon Utility Notification Center Is 1-800-332-2344.) <br /> 7/1/24:3:27:22PM Page 1 of 2 ONS_OnsiteAuthorization_pr <br />