Septic Permit 555-23-005790-PRMT Page 2 of 3
<br /> a��w.rr,�sx�* a�,a�� aa�t,�ear ��r �.�; z ,t„9,-,a� � ,� a"�fiy � + �^� a �. �.�z� „ �' z� .� ..rr; �>
<br /> tea a tQ.iti t o/2o N % 1 , 'i,d4 r,F �€ N� a K C f a d6'
<br /> � J�"` .; P � $ �.s> 44 f t ti
<br /> Word escri t 011:t tsr�J ICE 2 B4 M TflRf.' P� BC}RM .4 tv r�:t
<br /> y4t ,_ X � yt d n f .w 'hS1b fA1b . ,^' � d nKY4
<br /> troEIE>E�tlQns w ravaj
<br /> fib ,3-.,.. ..;, ..•fp°i,e.<r.,�w,a' ,. ,�. ,tom ,.. � � ,MA .,.. 1�!- ,; a....... .. ..*°vK?r„�,.,::,. �s� ...,. �.a.,�. ,. .wa,sr.:.w,rli
<br /> •This permit is for a new 1000 gallon tank and 170 feet of seepage trenches
<br /> •Requires single owner easement or property line adjustment.
<br /> •The existing chicken coop must be removed from the drainfield area,as it does not meet setbacks
<br /> -If any existing drainfield lines are found during excavation,the intersection must be sealed with bentonite clay.
<br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent).
<br /> •The system must be installed by the property owner or a licensed sewage disposal business(installer).
<br /> •Vehicular traffic and livestock must be restricted from the system area.
<br /> •All roof drains must be directed away from the system
<br /> •AII tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch minimum diameter if
<br /> less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain access to septic tank for pumping and
<br /> service.
<br /> •Meet all required setbacks
<br /> •The system must be installed in the area approved during the site evaluation and in accordance with the construction plan
<br /> approved by the agent, including any changes made by the agent.
<br /> All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or specifications without approval
<br /> by the agent.
<br /> •For product approval information and manufacturer installation requirements see DEQ website at:
<br /> http://www.oregon.govkleq/Residential/Pages/Onsite.aspx
<br /> •A minimum 18-gauge,green jacketed tracer wire or green color-coded metallic tape must be placed on top of the effluent sewer
<br /> or pressure transport pipe from tank to drainfield.
<br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length, level, and bedded.
<br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch.
<br /> •Maximum length of an individual trench is 150-feet.
<br /> •Serial distribution, each trench bottom to be level and on contour.Use Drop box(es).
<br /> Installation of this onsite wastewater treatment system has been determined to comply with the applicable requirements in
<br /> Oregon Administrative Rules Chapter 340, Divisions 071 and 073 and the Conditions of Approval above.
<br /> 1. In accordance with Oregon Revised Statute 454,665,this Certificate of Satisfactory Completion is issued as evidence of
<br /> satisfactory completion of an onsite wastewater treatment system at the location identified above.
<br /> 2. Issuance of this Certificate does not constitute a warranty or guarantee that this onsite wastewater treatment system will
<br /> function indefinitely without failure.Conditions imposed as permit requirements continue for the life of the system.
<br /> 3.The area of the initial and the identified replacement area must not be subjected to activity that is likely to adversely affect
<br /> the soil or the functioning of the system.Such activities may include, but are not limited to,vehicular traffic, livestock,
<br /> covering the area with asphalt or concrete,filling,cutting,or other soil modification activities.
<br /> 4.This onsite wastewater treatment system that be connected to the facility referenced herein within 5 years of the issuance
<br /> of this Certificate of Satisfactory Completion(CSC)or rules for authorization notices,alteration permits,or
<br /> construction-installation permits as outlined in OAR 340-071-0160,340-071-0205,or 340-071-0210 apply, including payment
<br /> of an additional fee.
<br /> 5.This system must operate in compliance with OAR Chapter 340, Division 071 and must not create a public health hazard
<br /> or pollute public waters.
<br /> 6. Unless otherwise required by the agent,the system installer must backfill(cover)this system within 10 days after the
<br /> issuance of this Certificate of Satisfactory Completion.
<br /> gP
<br /> •
<br /> K "d '` Nm a u i Cie CM#L Q SattS a„ o f Y.9-1PR PTI9Tre, vb ? . 14.Wi
<br /> System Inspection: Yes Operation of Law-7 Days Notice: No Pre-Cover Inspection Waived Per 340-071: No
<br /> Comments: Certificate of Satisfactory Completion issued on 06/26/2024.The system is authorized for connection.
<br /> i ompt etect CL15POP49FWtt i . � R
<br /> Inspector Inspection Inspection Date Inspection Result
<br /> Danielle Brown 7150 Septic System 06/25/2024 Approved
<br /> 6/27/24:12:05:16PM ONS_OnsiteCSC_pr