Laserfiche WebLink
• <br /> Onsite Permit 555-23-000172-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule"to 1-888-299-2821 use IVR Number:555083199292 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Date issued 11 9/23 f iwicp eft t 11t <br /> on da a 9(24 <br /> {AIOrk descrlptian NE t INSTAI L 613RM SFD �A <br /> ••; Os� G ;d Fi.tl& ��L <br /> Max depth: 30 in. Undisturbed soil between trenches: 8 ft. <br /> Min depth: 24 in. Capping fills-min depth of fill material: N/A <br /> li <br /> Special Requirements <br /> Groundwater type: Temporary Groundwater depth: 41 in. <br /> Pump to drainfield reqd: Yes Filter fabric on top of drain media: N/A <br /> Conditions of approval <br /> •An electrical permit and inspection from the Department of Consumer and Business Services, <br /> Building Codes Division,or the municipality with jurisdiction,is required for pump wiring installation. <br /> •Dry soil installation only(June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be.installed by the property owner or a licensed sewage disposal business(installer). <br /> •All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface.Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain <br /> access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must comply with <br /> applicable building,electrical,or other codes. <br /> •Install the pump and system components in accordance with the approved pump curve and specifications. <br /> •A minimum 18-gauge,green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Header pipe from Distribution or Drop Box must be minimum 4-ft length, level,and bedded. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. . <br /> •Serial distribution,each trench bottom to be level and on contour.Use Drop box(es). <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent,including any changes made by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or specifications <br /> without approval by the agent. <br /> •For product approval information and manufacturer installation requirements see DEQ website at: <br /> http://www.oregon.gov/deq/Residential/Pages/Onsite.aspx <br /> • <br /> • <br /> 1/19/23:12:32:12PM ONS_OnsitePermitpr <br />