Laserfiche WebLink
Onsite Permit 555-22-005281-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555044221320 <br /> Schedule using the Oregon ePermitting Inspection App, search "epermitting" in the app store <br /> Date"issued:7/5/22 Expiration date 7J5123 <br /> Work description:NEW INSTALL FOR NSFDS BORMM PARCEL#2 2.27 AC ,;!':-;Kr" <br /> Special Requirements <br /> Stake out required: Yes <br /> Groundwater type: Temporary Groundwater depth: 18 in. <br /> Pump to drainfield reqd: Yes Filter fabric on top of drain media: Yes <br /> Conditions of approval <br /> •Capping fill rules at OAR 340-071-0265.Construction must occur in dry soil conditions between June 1 and <br /> October 1 unless otherwise approved by the agent.The cap material must be pre-approved by the agent prior to <br /> placement. Minimum 10-ft between edge of fill and trench. Drainfield area must be scarified. Contact between <br /> native soil and fill must be mixed. Final cap to be seeded and or landscaped to prevent erosion. Protect from <br /> livestock and vehicular traffic. <br /> •Serial distribution.The cap material must be evenly graded to a final depth of 16-inches over the drain media. <br /> •All roof drains must be directed away from the system <br /> •The system must be installed by the property owner or a licensed sewage disposal business (installer). <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface. Twenty-inch <br /> minimum diameter if less than 36-in deep.Thirty-inch minimum diameter if greater than 36-in deep. Maintain <br /> access to septic tank for pumpingand service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance with the <br /> construction plan approved by the agent, including any changes made by the agent. <br /> •All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or specifications <br /> without approval by the agent. <br /> •An anti-buoyancy device is required for the septic tank(s)and must be installed as per the manufacturer <br /> installation guidelines. <br /> •A minimum 18-gauge, green-jacketed tracer wire or green color-coded metallic tape must be placed on top of <br /> the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Serial distribution, each trench bottom to be level and on contour. Use Drop box(es). <br /> 7/5/22:3:43:08PM ONS_OnsitePermit_pr <br />