Laserfiche WebLink
Onsite Permit 555-22-000881-PRMT Page 2 of 3 <br /> Schedule or track inspections at www.buildingpermits.oregon.gov <br /> Call or text the word "schedule" to 1-888-299-2821 use IVR Number:555027369176 <br /> Schedule using the Oregon ePermitting Inspection App, search"epermitting"in the app store <br /> Bate issuer �g �1i i • w Iratl tl `' 3 <br /> Work descripban NEW t44STA B D PRESSURIZED DISTRIBd T 6N 9 <br /> 3 � <br /> Max depth: 30 in. Undisturbed soil between trenches: 8 ft. <br /> Min depth: 18 in. Capping fills-min depth of fill material: N/A <br /> Special Requirements <br /> Stake out required: Yes <br /> Groundwater type: Permanent Groundwater depth: N/A <br /> Pump to drainfield reqd: Yes Filter fabric on top of drain media: N/A <br /> Other special rqmt: Orifices will need to be drilled at 1/8 inch and spaced every 24 inches,each lateral will need the last orifice to <br /> be drilled downward to allow for drainage of line. See attached documents for proper manifold configuration <br /> and construction <br /> Conditions of approval <br /> 'Pressurized distribution rules at OAR 340-071-0275. Install sweep elbows at ends of lateral piping <br /> with acceptable threaded plugs or caps. Minimum head of 5-ft at remotest orifice, less than 10% <br /> variation. Filter fabric required over drain media (rapidly permeable soils). The owner of a pressurized <br /> distribution system must maintain a contract with a certified maintenance provider to inspect, adjust <br /> and maintain the onsite system. The maintenance provider must submit an annual report and annual <br /> evaluation fee. <br /> •Dry soil installation only (June 1 —October 1 unless otherwise authorized by the agent). <br /> •The system must be installed by the property owner or a licensed sewage disposal business <br /> (installer). <br /> •Vehicular traffic and livestock must be restricted from the system area. <br /> 'All roof drains must be directed away from the system <br /> •All tanks must be tested for watertightness and have a water-tight riser to the ground surface. <br /> Twenty- inch minimum diameter if less than 36-in deep. Thirty-inch minimum diameter if greater than <br /> 36-in deep. Maintain access to septic tank for pumping and service. <br /> •Meet all required setbacks <br /> •The system must be installed in the area approved during the site evaluation and in accordance <br /> with the construction plan approved by the agent, including any changes made by the agent. <br /> 'All work is to conform to OAR 340, Division 71 and 73. Make no changes in system location or <br /> specifications without approval by the agent. <br /> •The pump and alarm must be wired on separate circuits in the control panel. Pump wiring must <br /> comply with applicable building, electrical, or other codes. An electrical permit and inspection from the <br /> Department of Consumer and Business Services, Building Codes Division, or the municipality with <br /> jurisdiction, is required for pump wiring installation. <br /> 'Install the pump and system components in accordance with the approved pump curve and <br /> specifications. <br /> 'A minimum 18-gauge, green-jacketed tracer wire or green color-coded metallic tape must be <br /> placed on top of the effluent sewer or pressure transport pipe from tank to drainfield. <br /> •Each drainfield trench must be level within a tolerance of plus or minus 1-inch. <br /> 3/9/22:8:09:27AM ONS_OnsitePermit_pr <br />